Improved Mathematical Model for a Single-ground Arcing Fault in Medium Voltage Distribution Networks

Jiaquan Ran1, Qing Yang1( ), Lewei He2, Hongwen Liu3, Tong Zhou1, Siyu Wei1
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400030, China
Chongqing Power Grid Co., Ltd., Chongqing 401220, China
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
Show Author Information

Abstract

Medium voltage distribution networks usually suffer from single-ground arcing fault, especially high impedance arcing fault. Moreover, induced intermittent arcing faults can severely endanger the reliability and safety of power systems. The arc model is important for high impedance arcing fault suppression and detection to effectively eliminate the single-ground arcing fault. This paper proposes an improved arc model, which is concise and explicit, based on a single-ground arcing fault conducted on a 10 kV experimental platform under different fault conditions. Characteristic parameters of single-ground arcing faults are obtained based on test results. Furthermore, characteristic parameters under different fault conditions of the improved arc model are presented. Finally, verification of the improved arc model is supported by PSCAD-EMTDC. Comparisons of the proposed arc model between three typical black-box arc models indicate that the proposed model has better performance and higher accuracy than that of the three typical arc models as fault resistance is in a range of 0.1 kΩ to 2.4 kΩ. Thus, its accuracy is acceptable and it is helpful to the simulation and suppression of arc fault overvoltage.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1937-1946

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ran J, Yang Q, He L, et al. Improved Mathematical Model for a Single-ground Arcing Fault in Medium Voltage Distribution Networks. CSEE Journal of Power and Energy Systems, 2025, 11(4): 1937-1946. https://doi.org/10.17775/CSEEJPES.2021.05120

1128

Views

60

Downloads

1

Crossref

6

Web of Science

7

Scopus

0

CSCD

Received: 15 July 2021
Revised: 05 October 2021
Accepted: 04 December 2021
Published: 18 August 2022
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).