Regular Paper | Open Access

Moisture Evaluation of Oil-immersed Insulation in Bushings Based on Frequency Domain Spectroscopy and Grey Relational Analysis

Xianhao FanSheng LiTengyue SunYiyi Zhang( )Jiefeng Liu
School of Electrical Engineering, Guangxi University, Nanning, China
Show Author Information

Abstract

Operation level and service life of oil-immersed bushings are related to the moisture inside theirs cellulose insulation. However, the parameters extracted by using existing frequency domain spectroscopy (FDS) based methods strongly depends on the data within a certain range or several sampling points, which could decrease the accuracy of extraction results if the measured FDS data is unreliable in the above regions. Given this issue, a universal and accessible tool is proposed to stimulate the change rule of FDS curves versus entire frequency regions, by which a set of feature parameters can be readily obtained by using the Taylor series model. Then, the database characterizing the moisture is established. An alternative method for evaluating the moisture in bushing cellulose insulation is proposed based on FDS and grey relational analysis (GRA). The feasibility and applicability of the proposed methods were later proved by the moisture evaluation of transformer oil-immersed bushings, in which the GRA is applied as a tool for moisture classification. The results showed that the average relative (absolute error) is less than 14.6% (0.17%). Thus, the proposed method can be preliminarily utilized for evaluating the moisture inside the bushing cellulose insulation.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 909-918

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Fan X, Li S, Sun T, et al. Moisture Evaluation of Oil-immersed Insulation in Bushings Based on Frequency Domain Spectroscopy and Grey Relational Analysis. CSEE Journal of Power and Energy Systems, 2025, 11(2): 909-918. https://doi.org/10.17775/CSEEJPES.2021.00510

439

Views

59

Downloads

3

Crossref

4

Web of Science

4

Scopus

0

CSCD

Received: 18 January 2021
Revised: 16 March 2021
Accepted: 26 May 2021
Published: 06 May 2025
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).