AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

DC Fault Current Calculation Method and Transient Characteristics of True Bipolar MMC-HVDC Systems

Botong Li1, Yichao Liu2( ), Bin Li1, Wenxin Wang1, Weijie Wen1, Xiaolong Chen1
key laboratory of smart grid of ministry of education, Tianjin University, Tianjin 300072, China
State Grid Tianjin Electric Power Company and the Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China
Show Author Information

Abstract

In this paper, the calculation method and transient characteristics of asymmetric faults in the DC side of a true bipolar system are studied. First, two typical MMC fault equivalent methods are analyzed, and comparison shows that active RLC equivalent branches are more suitable for fault analyses of a true bipolar system. Second, considering the influence of mutual impedance between the poles in DC side, a DC fault current calculation method for a true bipolar systems is proposed. Finally, the characteristics of transient electrical quantities including fault current and DC voltage in the process of DC faults in true bipolar systems are analyzed and summarized to provide references for the design of DC line insulation and relay protection schemes.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1704-1716

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li B, Liu Y, Li B, et al. DC Fault Current Calculation Method and Transient Characteristics of True Bipolar MMC-HVDC Systems. CSEE Journal of Power and Energy Systems, 2025, 11(4): 1704-1716. https://doi.org/10.17775/CSEEJPES.2021.00440

769

Views

50

Downloads

2

Crossref

10

Web of Science

10

Scopus

0

CSCD

Received: 14 January 2021
Revised: 09 May 2021
Accepted: 12 October 2021
Published: 05 September 2022
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).