AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Quantitative detection of 17β-estradiol in water and vegetable juice using an electrochemiluminescence immunosensor based on ZrO2 nanoparticles

Zhe LUO1,2, Feng YUAN1,2, Min LIAO1,2, Xiaomei XIE1,3( ), Yue XIAO1,2, Mingdi FAN1,2, Chunlin FAN4
State Key Laboratory of Soil Pollution Control and Safety, Zhejiang University, Hangzhou 310058, China
College of Environmental and Resource Science, Zhejiang University, Hangzhou 310058, China
National Demonstration Center for Experimental Environmental and Resources Education (Zhejiang University), Hangzhou 310058, China
Ningbo Ferno Biotechnology Co., Ltd., Ningbo 315502, China
Show Author Information

Abstract

Objective

Low-concentration 17β-estradiol (E2) in environmental media (µg/L or even lower) is one of the strongest endocrine disruptors in environmental estrogens. A quantitative analysis of E2 in the environment lacks sufficient sensitivity and accuracy. To fill the gap in existing environmental estrogen detection technology, electrochemiluminescence (ECL) and immunosensor techniques were combined to construct a nano-ZrO2 (ZrO2NPs)-based ECL immunosensor (ECLI). The potential of the immunosensor for detecting trace E2 was evaluated.

Methods

First, ZrO2NPs were prepared by a sol–gel method, and polyaniline (PANI)-coated gold nanoparticles (AuNPs) (PANI@AuNPs) were prepared using a gold nano seed coating method. Thereafter, ZrO2NPs were introduced onto the surface of a glass electrode (GCE), and sheep-derived E2 polyclonal antibody (Ab) was immobilized on the electrode to prepare a ZrO2NPs-based ECLI. Finally, the ECLI was immersed in the E2 test solution to capture E2, followed by the introduction of E2-labeled PANI@AuNPs (PANI@AuNPs-BSA-E2) to bind with Ab that was not pre-bound to E2. During this process, the electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and ECL response characteristics of the GCE surface at different stages of incubation were observed. The influence of the following factors on the ECL intensity of the ECLI during E2 detection was simultaneously investigated: substrate concentration, buffer solution environment (pH and co-reactant concentration), concentration of ZrO2NP suspension, potential scanning rate for ECL detection, Ab and E2 interaction time, and interaction time for Ab not bound to E2 with PANI@AuNPs-BSA-E2. E2 in the samples was quantitatively detected based on the relationship between the ECL intensity and E2 concentration. Finally, the stability, selectivity, regenerability, and applicability of the ECLI sensor for E2 detection in natural water and vegetable juice were investigated through 10 consecutive scans. Experiments were carried out by immersing the sensor in the sample for 1–12 days; replacing the target antigen E2 with diethylstilbestrol, estriol, estrone, dichlorodiphenyltrichloroethane, ethinylestradiol, or bisphenol A; adding E2 standard solution; regenerating the sensor via microwave desorption; and immersing it in natural water and vegetable juice samples containing a certain concentration of E2.

Results

The resistance of the multi-level sensor with the surface-modified GCE gradually increased. The ECL signal originated from bonding between Ab and E2 loaded on the surface of the ZrO2NPs. The optimal conditions for E2 detection by the ECLI were as follows: pH 7.0 buffer system; K2S2O8 (co-reactant) concentration of 100 mmol/L; ZrO2NPs suspension concentration of 2.5 g/L; Ab and E2; interaction time of 2.5 h for Ab not bound to E2 with PANI@AuNPs-BSA-E2; and potential scanning rate of 0.1 V/s. Under the optimal detection conditions, the ECL intensity of the ECLI exhibited a good linear response to the E2 concentration, with a correlation coefficient (R2) of 0.998 6 and a detection limit of 0.011 µg/L. After 10 consecutive scans and 12 days of storage, the ECL performance of the ECLI still reached ≥98% of its original level. The constructed ECLI was not affected by environmental endocrine disruptors. In natural water and vegetable juice, the recovery rate of E2 was in the range of 99.3%–104.0% and 98.7%–103.0%, respectively, indicating the satisfactory detection ability of the sensor. Regeneration using the ultrasound method indicated that ECLI had good regeneration and reusability.

Conclusions

The constructed ZrO2NPs-based ECLI sensor achieved quantitative detection of trace amounts of E2 in environmental samples, with good stability and selectivity, affording a wide detection range, low detection limit, and high sensitivity.

CLC number: TP212.2; TS207.5; X83 Document code: A Article ID: 1002-4956(2026)10-0050-08

References

【1】
【1】
 
 
Experimental Technology and Management
Pages 50-57

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LUO Z, YUAN F, LIAO M, et al. Quantitative detection of 17β-estradiol in water and vegetable juice using an electrochemiluminescence immunosensor based on ZrO2 nanoparticles. Experimental Technology and Management, 2026, 43(10): 50-57. https://doi.org/10.16791/j.cnki.sjg.2026.10.007

2

Views

0

Downloads

0

Crossref

0

Scopus

Received: 13 April 2026
Published: 20 October 2026
© 2026 Experimental Technology and Management. All rights reserved.

This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).