AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Risk Assessment and Hierarchical Prevention and Control Method for Active Distribution Networks With Large-Scale Integration of Distributed Photovoltaics

Honglue ZHANG1, Zhongqiang ZHOU1, Jingxin LUO2, Yixin XIA3, Chenxi XU4, Yuan ZHOU4( )
Power Dispatching and Control Center, Guizhou Power Grid Co., Ltd., Guiyang 550002, Guizhou Province, China
Duyun Power Supply Bureau, Guizhou Power Grid Co., Ltd., Duyun 558000, Guizhou Province, China
Bijie Power Supply Bureau, Guizhou Power Grid Co., Ltd., Bijie 551700, Guizhou Province, China
Department of Power Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China
Show Author Information

Abstract

High penetration of distributed photovoltaic (PV) generation can cause voltage violations, branch overloading, reverse power flow, and increased operating stress on grid-interface equipment. To address these problems, this study proposes an operational risk assessment and hierarchical prevention and control method for active distribution networks. A multidimensional risk index system is first developed to characterize nodal voltage, branch power flow, reverse power flow, and main-transformer overloading. PV output uncertainty is represented using a mixed Beta distribution and Monte Carlo sampling, while the risk-index weights are determined using the entropy weighting method. A four-level prevention and control scheme is then established, comprising normal monitoring, flexible mitigation, coordinated accommodation, and emergency response. The participation ranges of energy storage systems, reactive power compensation, and demand response are configured according to the uncontrolled-state safety trigger and PV penetration. A bi-objective optimization model is subsequently formulated to minimize comprehensive operational risk and control cost. NSGA-II is employed to obtain the Pareto-optimal solution set, and the minimum Euclidean-distance method is used to select the compromise control solution. Results from the IEEE 33-bus system show that, at 100% PV penetration, the comprehensive operational risk decreases from 0.8330 to 0.16, with a control cost of 339.5 yuan. Compared with the expert strategy and the economic-only optimization method, the proposed method reduces operational risk by 88.06% and 69.26%, respectively. It also achieves performance comparable to all-resource unified optimization with a smaller optimization dimension. These results demonstrate that the proposed method effectively mitigates the operational risks caused by high PV penetration while balancing system security and control economy.

CLC number: TK 01;TM 732 Document code: A

References

【1】
【1】
 
 
Distributed Energy
Pages 40-51

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG H, ZHOU Z, LUO J, et al. Risk Assessment and Hierarchical Prevention and Control Method for Active Distribution Networks With Large-Scale Integration of Distributed Photovoltaics. Distributed Energy, 2026, 11(5): 40-51. https://doi.org/10.16513/j.2096-2185.DE.26110345

1

Views

1

Downloads

0

Crossref

Received: 10 July 2026
Revised: 14 August 2026
Published: 25 October 2026
© Editorial Department of Distributed Energy Journal 2026. Published by Tsinghua University Press.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).