AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Low-Carbon Optimal Configuration of a Mine Clean Energy System Over Its Full Life Cycle

Jianfeng HUANG1, Hailong LIU2,3, Yingxin MOU1, Rui LIANG2( ), Yuxuan CHENG2
SDIC Hami Energy Development Co., Ltd., Hami 839000, Xinjiang Uygur Autonomous Region, China
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, Jiangsu Province, China
China National Coal Group Xinjiang Energy Co., Ltd., Urumqi 830011, Xinjiang Uygur Autonomous Region, China
Show Author Information

Abstract

To address renewable energy accommodation difficulties and supply-demand imbalances caused by mismatches between evolving loads and renewable generation over the full life cycle of mining areas in western China, a dynamic configuration method is proposed for clean energy systems in underground coal mines. Based on the load characteristics of four stages—construction, early-stage mining, mid-stage mining, and late-stage mining—a multistage optimal configuration model is established that includes photovoltaic generation, energy storage, chillers, and external electricity and heat supplies. The model optimizes the capacities of photovoltaic systems, energy storage, and primary electrical equipment by minimizing the full life cycle costs of investment, operation and maintenance, purchased energy, and carbon emissions. A coal mine in western China is used to compare static and dynamic configuration scenarios. The results show that, compared to the static scenario without energy storage, the dynamic scenario increases photovoltaic and energy storage deployment, reduces the average capacity of primary electrical equipment, and lowers the total cost over the full life cycle and carbon emission cost by approximately 17.9% and 50.2%, respectively. The method provides a reference for planning clean energy systems in mining areas and similar energy-intensive industrial parks.

CLC number: TK 01 Document code: A

References

【1】
【1】
 
 
Distributed Energy
Pages 129-138

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HUANG J, LIU H, MOU Y, et al. Low-Carbon Optimal Configuration of a Mine Clean Energy System Over Its Full Life Cycle. Distributed Energy, 2026, 11(5): 129-138. https://doi.org/10.16513/j.2096-2185.DE.25100499

1

Views

0

Downloads

0

Crossref

Received: 16 December 2025
Revised: 21 January 2026
Published: 25 October 2026
© Editorial Department of Distributed Energy Journal 2026. Published by Tsinghua University Press.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).