AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Dynamic Simulation and Economic Analysis of 10 MW-Class Distributed Compressed Air Energy Storage System

Xiaoyu YUE1, Chao XIA1, Yongle ZHAO1( ), Mengzhe WANG2
Xi’an XD Electric Research Institute Co., Ltd., Xi’an 710075, Shaanxi Province, China
Xi’an XD Power Electronics Co., Ltd., Xi’an 710075, Shaanxi Province, China
Show Author Information

Abstract

Compared with salt caverns and artificial cavities, using pipeline steel as above-ground gas storage chambers offers greater advantages for small-scale distributed compressed air energy storage (CAES) systems. This paper establishes a detailed dynamic simulation model of a 10 MW-class distributed CAES system based on AMESIM software. The research investigates key parameters such as discharge duration, above-ground storage chamber volume, system efficiency, and energy storage density under different energy storage durations and different maximum storage pressures of the above-ground storage chambers. In addition, an economic analysis of the system is also conducted. The results show that heat loss of the thermal storage and exchange system is the main cause of energy loss in the CAES system. As the energy storage duration increases, the volume of above-ground storage chambers increases, while the system efficiency remains unchanged and energy storage density increases, meanwhile, the reduction rate of the static payback period gradually slows down. With an increase of maximum ground chamber pressure, the chamber volume decreases, system efficiency declines and energy storage density increases, while the static payback period first declines and then rises. When the maximum pressure of the above-ground chamber rises from 9 MPa to 14 MPa, the system efficiency drops from 67.59% to 54.37%. The minimum static payback period of 8.29 years is achieved at the optimal pressure of 11.8 MPa.

CLC number: TK02 Document code: A

References

【1】
【1】
 
 
Distributed Energy
Pages 119-132

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YUE X, XIA C, ZHAO Y, et al. Dynamic Simulation and Economic Analysis of 10 MW-Class Distributed Compressed Air Energy Storage System. Distributed Energy, 2025, 10(6): 119-132. https://doi.org/10.16513/j.2096-2185.DE.25100356

584

Views

14

Downloads

0

Crossref

Received: 22 September 2025
Published: 01 December 2025
© Editorial Department of Distributed Energy Journal