AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (13.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Ground source heat pump heating of embankments in cold regions to eliminate frost heave

Tianfei HU1,2( ), Li WANG3
State Key Laboratory of Mechanical Behavior and System Safety of Traffic Engineering Structures, Shijiazhuang Tiedao University, Shijiazhuang 050043, China
Key Laboratory of Mechanical Behavior Evolution and Control of Traffic Engineering Structures in Hebei, Shijiazhuang Tiedao University, Shijiazhuang 050043, China
School of Civil Engineering, Shijiazhuang Tiedao University, Shijiazhuang 050043, China
Show Author Information

Abstract

A ground source heat pump system was designed for heating embankments to eliminate frost heave. Tests showed that the device can automatically output heating temperatures of 40, 50, or 60℃ with coefficients of performance greater than 3.0. The heating influenced a 0.76 m radius region on the 1st day, 1.64 m on the 5th day, and 2.30 m on the 10th day. A case study showed that the central freezing depth of an embankment was 0.89 m for standard conditions but was reduced to less than 0.2 m with artificial heating. The soil temperature rise and the heat diffusion both increased with increased heating temperature. Rapid thawing and emergency rescues during frost heave conditions require that the heat pumps have longitudinal spacings along the embankment of 2.0-4.0 m and heating capacities of 1.0-2.0 kW.

CLC number: TU442 Document code: A Article ID: 1000-0054(2022)05-0871-10

References

【1】
【1】
 
 
Journal of Tsinghua University (Science and Technology)
Pages 871-880

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HU T, WANG L. Ground source heat pump heating of embankments in cold regions to eliminate frost heave. Journal of Tsinghua University (Science and Technology), 2022, 62(5): 871-880. https://doi.org/10.16511/j.cnki.qhdxxb.2022.21.007

817

Views

5

Downloads

0

Crossref

6

Scopus

5

CSCD

Received: 13 December 2021
Published: 15 May 2022
© Journal of Tsinghua University (Science and Technology). All rights reserved.