AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Application of the One-step mRNA-PCR Fluorescence Multiplex Amplification Detection System in Forensic Cases

Li ZHAO1, Yixia ZHAO2, Jinping SONG1, Feng GAO1, Aiqiang LI1, Yanxia ZHANG1, Xianghua WANG1, Sheng HU2, Qifan SUN2, Anquan JI2( )
Institute of Forensic Science, Hebei Provincial Public Security Department, Shijiazhuang 050000, China
Institute of Forensic Science, Ministry of Public Security(MPS) & National Engineering Laboratory for Forensic Science & MPS’ Key Laboratory of Forensic Genetics, Beijing 100038, China
Show Author Information

Abstract

To evaluate the application potential of the one-step mRNA-PCR fluorescence multiplex amplification detection technology for identifying body fluid stains in case samples, a total of 89 samples suspected to be blood, saliva, semen, and vaginal secretions were collected. These samples were analyzed collaboratively with two forensic DNA laboratories lacking prior RNA operation experience. The laboratories performed total RNA extraction, one-step RT-PCR amplification, and capillary electrophoresis detection using different experimental instruments. The results demonstrated that three housekeeping genes (GAPDH, ACTB, and PRL19) were successfully detected in all 89 case samples. Additionally, specific markers for each body fluid were identified: HBB and HBA for peripheral blood; MMP7 and MMP10 for menstrual blood; STATH and HTN3 for saliva; PRM2 and SEMG1 for semen; and CYP2B7P1 and HBD1 for vaginal fluid. Notably, each participating DNA laboratory was able to independently complete the detection of RNA markers in the case samples, and parallel testing of the same samples across different laboratories yielded consistent results. This study provides robust evidence supporting the application of the one-step mRNA-PCR fluorescence multiplex amplification detection system for the source identification of body fluid stains in forensic case samples.

CLC number: DF795.2 Document code: A Article ID: 1008-3650(2026)03-0266-06

References

【1】
【1】
 
 
Forensic Science and Technology
Pages 266-271

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHAO L, ZHAO Y, SONG J, et al. Application of the One-step mRNA-PCR Fluorescence Multiplex Amplification Detection System in Forensic Cases. Forensic Science and Technology, 2026, 51(3): 266-271. https://doi.org/10.16467/j.1008-3650.2025.0026

1

Views

0

Downloads

0

Crossref

0

Scopus

Received: 12 August 2024
Revised: 28 February 2025
Published: 27 April 2025
© 2026 The Editorial Office of Forensic Science and Technology

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).