AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Determination of Difenidol and Diphenhydramine in Blood Samples by Ultrasonic-assisted Ionic Liquid-based Dispersive Liquid-liquid Microextraction Coupled with LC-MS/MS

Yanhua SHI1Yun SUN1Yue GUO1Qinglin GUAN2Tao WANG1Meng HU1Zhiwen WEI1Keming YUN1Haiyan CUI1( )
School of Forensic Medicine, Shanxi Medical University & Key Laboratory of Forensic Toxicology, Ministry of Public Security, Jinzhong 030600, Shanxi, China
School of Medicine, Shaoxing University, Shaoxing 312000, Zhejiang, China
Show Author Information

Abstract

A method for the determination of difenidol and diphenhydramine in blood samples utilizing ultrasonic-assisted ionic liquid dispersive liquid-liquid microextraction coupled with LC-MS/MS was established. 1-butyl-3-methylimidazolium hexafluorophosphate ([Bmim][PF6]) was used as the extractant, and acetone was used as the dispersant. The samples were separated by a ZORBAX Eclipse Plus C18 RRHD column. Aqueous solution containing 0.1% formic acid and methanol was used as mobile phases. A gradient elution mode was employed with a flow rate of 0.2 mL/min, followed by electrospray ion source mode (ESI+) analysis in scheduled multiple reaction monitoring mode (MRM). The detection limits of difenidol and diphenhydramine in blood samples were 0.01 ng/mL, and the quantification limits were 0.02 ng/mL for both. The intraday and interday precisions (relative standard deviation, RSD) were both less than 20%, and the relative recovery rates ranged from 98.38% to 115.10%. The concentrations of difenidol and diphenhydramine in the blood of a fatal case were 4.02 µg/mL and 3.78 µg/mL, respectively. This study demonstrated the feasibility of using ultrasonic-assisted ionic liquid dispersive liquid-liquid microextraction combined with LC-MS/MS for the determination of difenidol and diphenhydramine in blood samples. The method has the advantages of environmentally friendly, high enrichment efficiency, and high sensitivity, making it suitable for forensic identification of difenidol and diphenhydramine.

CLC number: DF795.1 Document code: A Article ID: 1008-3650(2026)02-0142-07

References

【1】
【1】
 
 
Forensic Science and Technology
Pages 142-148

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
SHI Y, SUN Y, GUO Y, et al. Determination of Difenidol and Diphenhydramine in Blood Samples by Ultrasonic-assisted Ionic Liquid-based Dispersive Liquid-liquid Microextraction Coupled with LC-MS/MS. Forensic Science and Technology, 2026, 51(2): 142-148. https://doi.org/10.16467/j.1008-3650.2025.0002

0

Views

0

Downloads

0

Crossref

0

Scopus

Received: 19 April 2024
Revised: 02 September 2024
Published: 07 January 2025
© 2026 The Editorial Office of Forensic Science and Technology

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).