AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Determination of Five Common Fluorinated Anesthetics and Hexafluoroisopropanol in Blood Samples by HS-GC-MS

Ji MA1( )Lei ZHANG1Yali FANG2
Forensic Science Center of Dongguan Public Security Bureau, Dongguan 523000, Guangdong, China
Scientific Research Platform Service Management Center, Guangdong Medical University, Dongguan 523000, Guangdong, China
Show Author Information

Abstract

This paper aims to establish a headspace (HS) gas chromatography-mass spectrometry (GC-MS) method for the detection of sevoflurane, desflurane, enflurane, isoflurane, halothane and hexafluoroisopropanol in biological samples. Blood samples (1.0 mL) and equivalent volume of deionized water were added into a 10 mL headspace vial, before the vial was sealed. The vial was extracted at 65 ºC for 5 minutes and then the headspace was analyzed by GC-MS (EI), with the data being acquired under full scan mode. Sevoflurane, desflurane, enflurane, isoflurane, halothane and hexafluoroisopropanol showed good linear relationship between peak area and concentration within the investigated concentration ranges, with their coefficients of determination(R2) being over 0.990 2. The lower limit of detection (LLOD) and limit of quantification (LOQ) for six analytes ranged 0.04-0.5 μg/mL and 0.06-1 μg/mL, respectively. Their average recoveries among 61.19%-90.39%. The precision (RSD) of intra-day and inter-day behaved satisfied between 1.62%-17.29% and 0.85%-17.91%. The method is of high speed, simplicity, efficiency and low interference for determination of sevoflurane, desflurane, enflurane, isoflurane, halothane and hexafluoroisopropanol.

CLC number: DF795.1 Document code: A Article ID: 1008-3650(2025)03-0285-06

References

【1】
【1】
 
 
Forensic Science and Technology
Pages 285-290

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
MA J, ZHANG L, FANG Y. Determination of Five Common Fluorinated Anesthetics and Hexafluoroisopropanol in Blood Samples by HS-GC-MS. Forensic Science and Technology, 2025, 50(3): 285-290. https://doi.org/10.16467/j.1008-3650.2024.0074

0

Views

0

Downloads

0

Crossref

0

Scopus

Received: 27 October 2023
Revised: 26 June 2024
Published: 08 November 2024
© 2025 The Editorial Office of Forensic Science and Technology

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).