AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Publishing Language: Chinese | Open Access

Identification of a New Synthetic Cathinone 2-dimethylamino-1-[3,4-(methylenedioxy)phenyl]-1-pentanone

Binshu JIN( )Ping WANGXiaoyun LIUHaoquan GUANDehang LUOHang ZHOUGuiqiao LIANG
Guangzhou Accurate and Correct Test Company, Guangdong Accurate and Correct Institution of Forensic Sciences, Guangzhou 510663, China
Show Author Information

Abstract

The means and forms of drug transmission are becoming increasingly diverse, posing significant challenges to public security investigations, laws and regulations supervision, and identification technology. In terms of identification technology, the detection of isomers, which can easily lead to misjudgments, remains particularly challenging. The comprehensive analysis of multidimensional detection methods has emerged as a trend in addressing the identification and regulation of new psychoactive substances. Currently, a notable synthetic cathinone called 2-dimethylamino-1-[3,4-(methylenedioxy)phenyl]-1-pentanone(N,N-dimethylpentylone) warrants attention. This paper aims to develop an analytical method for identifying N,N-dimethylpentylone as a new synthetic cathinone. The processed unknown samples are analyzed using a combination of gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), nuclear magnetic resonance (NMR) including 1H-NMR, 13C-NMR, H-H COSY, HSQC, HMBC, and Fourier transform infrared spectroscopy (FTIR). GC-MS analysis results show that the qualitative ion fragments are m/z 100.1, m/z 58.1, m/z 121.1, m/z 149.0, with a retention time at 11.888 minutes. LC/MS analysis results show that the parent ion is m/z 250.05, and the product ions are m/z 100.10, m/z 205.10, and m/z 135.10, with a retention time at 9.772 minutes. FTIR analysis results show that there area carbonyl absorption peak at 1676 cm-1, and a benzene ring vibration absorption peak at 1506 and 1441cm-1. One-dimensional nuclear magnetic spectrum results show 9 hydrogen signals with different chemical shifts and 14 carbon signals with different chemical shifts in the unknown compound. Two-dimensional NMR analysis results show that the unknown compound conforms to the structure of N,N-dimethylpentylone. In summary, N,N-dimethylphenylone components are detected in the unknown sample.

CLC number: DF795.1 Document code: A Article ID: 1008-3650(2025)02-0175-07

References

【1】
【1】
 
 
Forensic Science and Technology
Pages 175-181

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
JIN B, WANG P, LIU X, et al. Identification of a New Synthetic Cathinone 2-dimethylamino-1-[3,4-(methylenedioxy)phenyl]-1-pentanone. Forensic Science and Technology, 2025, 50(2): 175-181. https://doi.org/10.16467/j.1008-3650.2024.0025

0

Views

0

Downloads

0

Crossref

0

Scopus

Received: 07 July 2023
Revised: 05 January 2024
Published: 08 April 2024
© 2025 The Editorial Office of Forensic Science and Technology

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).