AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research paper | Publishing Language: Chinese

Prediction Model of Indoor Bioaerosol Concentrations—A Case Study of Qingdao

Ru Zhao1,2, Liang Guo3, Jianhua Qi1,2( )
Key Laboratory of Marine Environment and Ecology, Ministry of Education, Ocean University of China, Qingdao 266100, China
College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China
Qingdao Junray Intelligent Instrument Limited Company, Qingdao 266108, China
Show Author Information

Abstract

The deposition of bioaerosols in the respiratory system may induce respiratory diseases. Given that modern populations spend approximately 90% of their time indoors, predicting indoor bioaerosol concentrations is crucial for health risk prevention and control. This study collected samples from offices and laboratories in three universities in Qingdao. Using DAPI staining and LIVE/DEADⓇ BacLightTM staining combined with fluorescence microscopy, we measured the concentrations of total airborne microorganisms (TAMs), viable bacteria (VBs), and non-viable bacteria (NVBs). The experimental results showed that the concentration of VBs ranged from 0.10×104~1.97×104 cells/m3, while NVBs and TAMs ranging from 3.11×104~12.63×104 cells/m3 and 1.09×104~9.42×105 cells/m3, respectively. To investigate the relationship between indoor TAMs concentrations and environmental factors, we compared the performance of multiple linear regression (MLR), Ridge regression, and Poisson regression models. The results revealed that MLR had limited predictive capability, Ridge regression could not adequately explain all variables, while the Poisson regression model provided a more accurate explanation and prediction of bioaerosol concentrations. The analysis indicated that temperature, relative humidity (RH), particulate matter concentration, and human activities collectively influence microbial concentrations, with PM10 and RH showing the most significant effects. The low-cost predictive model developed in this study provides a theoretical foundation for indoor air quality management.

CLC number: X513 Document code: A Article ID: 1672-5174(2026)01-094-14

References

【1】
【1】
 
 
Periodical of Ocean University of China
Pages 94-107

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhao R, Guo L, Qi J. Prediction Model of Indoor Bioaerosol Concentrations—A Case Study of Qingdao. Periodical of Ocean University of China, 2026, 56(1): 94-107. https://doi.org/10.16441/j.cnki.hdxb.20250076

1076

Views

14

Downloads

0

Crossref

0

CSCD

Received: 08 March 2025
Revised: 06 April 2025
Published: 01 January 2026
© Periodical of Ocean University of China