AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Medicine | Publishing Language: Chinese | Open Access

Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment

Juntao HU1,2, Sui LI2, Yun LIU1( )
Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing
Department of Radiology, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China
Show Author Information

Abstract

Objective

To investigate the feasibility of reducing radiation dose in cerebral perfusion CT (CTP) while maintaining diagnostic accuracy by optimizing temporal resolution.

Methods

This retrospective cohort study included 117 stroke-suspected patients undergoing CTP at the First Affiliated Hospital of Army Medical University from January to September 2025. Three protocols were designed: Protocol 1 (full temporal resolution, 21-phase acquisition, baseline), Protocol 2 (every-other-phase sampling), Protocol 3 (peak-enhancement+1/-1 phase retention with every-other-phase sampling for remaining phases). Radiation reduction percentages relative to Protocol 1 were calculated. Regions of interest (ROI) were placed in ischemic core/penumbra to measure mean±SD of perfusion parameters: time to maximum of the residue function (Tmax), mean transit time (MTT), cerebral blood volume (CBV) and cerebral blood flow (CBF). Inter-protocol differences were assessed, and ischemic penumbra volume discrepancies were also analyzed.

Results

Protocol 2 and 3 reduced radiation dose by 50.0% and 42.9% versus Protocol 1, respectively. For perfusion parameters: Tmax SD differed significantly across protocols [F(1.92, 222.42)=11.17, P<0.001, partial η2=0.09]; post hoc tests showed significant mean differences between Protocol 1 vs 2 (P<0.016 7) and Protocol 1 vs 3 (P<0.016 7), but not Protocol 2 vs 3. MTT means showed no significant difference [F(1.88, 218.11)=0.47, partial η2=0.004], though SD differed significantly between Protocol 1 vs 2 and 1 vs 3 (P<0.016 7). CBV SD differed significantly [F(1.98, 229.25)=22.97, P<0.001, partial η2=0.17] with no mean difference (Friedman test). CBF means showed no significant difference (Bonferroni-adjusted) but SD differed significantly between Protocol 1 vs 2 and 1 vs 3 (P<0.016 7). Ischemic penumbra volumes differed significantly across all protocols (P<0.016 7).

Conclusion

Temporal resolution optimization significantly reduces CTP radiation dose while minimally impacting core perfusion parameters (MTT, CBV, CBF means). CBF remained stable across reduced-dose protocols and may serve as a reliable diagnostic criterion for infarct core delineation.

CLC number: R743.33; R814.2; R816.1 Document code: A

References

【1】
【1】
 
 
Journal of Army Medical University
Pages 461-469

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HU J, LI S, LIU Y. Optimizing temporal resolution to reduce radiation dose in cerebral perfusion CT: a feasibility and stability study based on perfusion parameter assessment. Journal of Army Medical University, 2026, 48(4): 461-469. https://doi.org/10.16016/j.2097-0927.202511101

475

Views

6

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 21 November 2025
Revised: 15 January 2026
Published: 28 February 2026
© 2026 Journal of Army Medical University

This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).