Application effect of a non-contact sleep monitoring mattress based on body movement characteristics during sleep

Yanchun ZHANGYan LIURui WANGFeilong WANGYue ZHAOFei LITunan CHENJishu XIAN( )
Department of Neurosurgery, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, China
Show Author Information

Abstract

Objective

To verify the accuracy of a Non-Contact Sleep Monitoring Mattress(NCSMM based on body movement during sleep in assessing sleep quality of patients before neurosurgery in order to provide a more portable and efficient assessment tool for clinical staff.

Methods

A single-arm trial was conducted on 114 inpatients admitted in our department selected with convenience sampling. Sleep quality data of 1 night were collected through 5 sleep quality assessment tools, including NCSMM, polysomnography(PSG), Patient-Reported Outcome Measurement Information System(PROMIS) Sleep Disturbance scale,Richards-Campbell Sleep Scale(RCSQ), and a wearable device(smart watch for body movements and sleep quality monitoring). The sleep efficiency(≤85%) obtained by PSG was used as the diagnostic standard for sleep disorders. The area under the receiver operating characteristic curve(AUC), sensitivity, specificity,positive predictive value, negative predictive value, and Youden index were calculated for the other 4 tools to evaluate and compare their diagnostic effectiveness.

Results

The AUC value for NCSMM, PROMIS, RCSQ and smart watch was 0. 788(95%CI: 0. 687~0. 888, P<0. 001), 0. 664(95%CI: 0. 543~0. 784, P=0. 02),0. 723(95%CI: 0. 600~0. 846, P=0. 001) and 0. 750(95%CI: 0. 654~0. 846, P<0. 001), respectively. The diagnostic accuracy rate was 0. 774, 0. 559, 0. 742 and 0. 602, with corresponding Youden index value of 0. 488, 0. 321, 0. 456, and 0. 459. NCSMM demonstrated the best AUC value, sensitivity and Youden index when compared with the other 3 tools.

Conclusion

NCSMM shows high accuracy in assessing sleep quality in pre-neurosurgery inpatients, and it is a viable portable and efficient assessment tool in clinical practice.

CLC number: R338.6; R473.74; R741.041 Document code: A

References

【1】
【1】
 
 
Journal of Army Medical University
Pages 326-334

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG Y, LIU Y, WANG R, et al. Application effect of a non-contact sleep monitoring mattress based on body movement characteristics during sleep. Journal of Army Medical University, 2025, 47(4): 326-334. https://doi.org/10.16016/j.2097-0927.202410073

4

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 21 October 2024
Revised: 18 November 2024
Published: 28 February 2025
© 2025 Journal of Army Medical University

This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).