AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (779.4 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Accuracy of new generation intraocular lens formula for patients with high myopia undergoing combined anterior and posterior segment surgery

Liang TAOXu CHENChao WANHe ZHAOLongwang WUZui TAONan WUXi LIUYong LIU( )
Department of Ophthalmology, First Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
Show Author Information

Abstract

Objective

To analyze the accuracy of the new generation intraocular lens (IOL) formula and the Wang-Koch (WK) adjustment in individuals with severe myopia undergoing combined anterior-posterior surgery.

Methods

A total of 100 patients (100 eyes) with axial length (AL) >26 mm undergoing combined anterior and posterior segment surgery in our department from June 2015 to June 2021 were enrolled in this study. Totally 13 IOL calculation formulas, such as Barrett Universal Ⅱ (BUⅡ), Emmetropia Verifying Optical (EVO), Kane, Haigis, Hoffer Q, Holladay, and SRK/T as well as the first generation linear WK eye axis optimization formula (Haigis-WK1, SRK/T-WK1, Hoffer Q-WK1, Holladay 1-WK1) and the second generation linear WK eye axis optimization formula (SRK/T-WK2, Holladay 1-WK2), were utilized to determine IOL diopter. The mean prediction error (ME), mean absolute error (MAE), median absolute error (MedAE), and percentage of prediction error within different refractive thresholds were calculated to assess the accuracy of each formula. In order to investigate the impact of AL on accuracy of IOL calculation, the patients were categorized into group A (38 eyes, 26.00 mm<AL≤28.00 mm), group B (28 eyes, 28.00 mm<AL≤30.00 mm), and group C (34 eyes, AL >30.00 mm). Additionally, the patients were also divided into silicone oil (63 eyes) and non-silicone oil (37 eyes) groups based on preoperative intraocular filling to determine the effect of intraocular filling on IOL calculation.

Results

The MedAE values of the new-generation IOL formulas (BUⅡ, EVO, and Kane) were significantly lower (0.34D, 0.31D, 0.35D) than those of traditional formulas (P<0.05). Additionally, the percentage of prediction errors within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D were significantly higher with the new formulas when compared to traditional ones (P<0.05). Traditional formulas exhibited a hyperopic deviation (0.35D~0.65 D), which could be corrected using the WK eye axis adjustment. WK2 was effective in improving the accuracy of calculation in SRK/T and Holladay 1 formulas, and there was no statistical difference in the MedAE values of SRK/T-WK2 and Holladay 1-WK2 formulas with the new-generation IOL formulas. When comparing the formulas across different axial eye length groups in terms of MedAE, the new IOL formulas (BUⅡ, kane and EVO) and WK-corrected formulas (Haigis-WK1, SRK/T-WK1, SRK/T-WK2, Hoffer Q-WK1, Holladay 1-WK1, Holladay 1-WK2) showed no significant differences among the different AL groups. However, there were significant differences in the MedAE values of traditional formulas among the different AL groups (P<0.01), with group C displaying the largest MedAE values (Haigis: 0.84D, SRK/T: 1.10D, Hoffer Q: 1.23D, Holladay 1: 1.20D). Comparing the MedAE values of different formulas in various preoperative intraocular filling groups, it was observed that the MedAE values of the new-generation IOL formulas (BUⅡ, kane and EVO), Haigis, and SRK/T formulas were significantly higher in the silicone oil-filled eye group than the non-silicone oil-filled eye group (P<0.05).

Conclusion

In patients with high myopia undergoing combined anterior and posterior segment surgery, the precision and consistency of the new-generation IOL formulas and the second-generation linear WK axis correction formula exhibit significant improvements when compared to traditional formulas.

CLC number: R311;R778.11;R779.6 Document code: A

References

【1】
【1】
 
 
Journal of Army Medical University
Pages 1545-1552

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
TAO L, CHEN X, WAN C, et al. Accuracy of new generation intraocular lens formula for patients with high myopia undergoing combined anterior and posterior segment surgery. Journal of Army Medical University, 2024, 46(13): 1545-1552. https://doi.org/10.16016/j.2097-0927.202310065

763

Views

9

Downloads

0

Crossref

1

Scopus

1

CSCD

Received: 26 October 2023
Revised: 20 December 2023
Published: 15 July 2024
© 2024 Journal of Army Medical University