Disease investigation of single-storey masonry structure in tropical island villages and related performance analysis of service materials

Yubo HUI1Fei ZHAO1Haibin ZHANG1Wei WANG2Feiyu HAN1Zhi ZHOU1 ( )
School of Civil Engineering and Architecture, Hainan University, Haikou 570228, China
School of Information and Communication Engineering, Hainan University, Haikou 570228, China
Show Author Information

Abstract

Hainan Island is located in the tropical marine monsoon climate zone, and the masonry structures of villages and towns on the island are exposed to the complex and harsh environments, such as high temperature, high humidity, high salt spray, and high ultraviolet rays. Because of the limitations of masonry mode and construction technology, under the action of random loads, the masonry structure houses in the place are easy to be damaged. Because they have been affected by the complex environment for many years, and the effective repair measures are lacked, there are greater safety hazards in a number of civil masonry houses, which seriously reduced their service life. Until now, the masonry houses are still the main form of the construction in Hainan villages and towns. In the report, Baoting County, Hainan Province was used as an example, the quality disease data of 1614 single-storey masonry houses in the region were counted, the failure forms and the possible causes of single-storey masonry structures in tropical island villages and towns were analyzed and summarized, and the mechanical properties of the masonry materials of typical active masonry structures were tested. The results indicated that within the length of service, the minimum strength retention rate and maximum strength retention of the red brick sample was 23.7%, 173.5%, respectively; the minimum strength retention rate and maximum strength retention of the steel sample was 55.9%, 112.4%, respectively.

CLC number: TU398+.5 Document code: A Article ID: 1004-1729(2025)02-0137-09

References

【1】
【1】
 
 
Natural Science of Hainan University
Pages 137-145

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
HUI Y, ZHAO F, ZHANG H, et al. Disease investigation of single-storey masonry structure in tropical island villages and related performance analysis of service materials. Natural Science of Hainan University, 2025, 43(2): 137-145. https://doi.org/10.15886/j.cnki.hdxbzkb.2024031002

385

Views

1

Downloads

0

Crossref

Received: 10 March 2024
Published: 25 April 2025
© The Author(s).

This is an open access article under the CC-BY license (http://creativecommons.org/licenses/by/4.0/).