In order to solve the problem that the glued laminated wood beam web shear damage occurs when the glued laminated wood beam is loaded in bending because of the low shear strength of the web, without giving full play to the tensile and compressive capacity of the wood.
In this paper, a new steel-wood combination I-beam with the web being an I-beam and the upper and lower wood plates bolted together was designed and subjected to three-equal point bending loading comparison tests together with glued laminated wood beams to observe the damage modes, mid-span deflection changes, section height and strain development of the wing plates of the steel-wood combination beam and glued laminated wood beam, respectively, to study the cross-sectional load capacity of the two structural beams.
The test results showed that the damage mode of the glued woodworking beam was brittle with plain shear damage; the damage of the timber-steel combination I-beam was yielding of the steel web and plain shear damage of the wood flange; the ultimate load, initial stiffness and strength reserve of the timber-steel combination I-beam were 79.7%, 3.2% and 140.1% higher than those of the glued woodworking beam; the maximum longitudinal compressive strain of the wood flange of the top plate of the wood-steel combination I-beam was 2.08 times higher than that of the glued woodworking beam when the ultimate load was reached, and the longitudinal tensile strain of the timber flange of the bottom plate was 2.75 times that of the glued laminated timber beam.
The wood-steel composite I-beam is a scientific and reasonable combination form, which not only effectively solves the problem of shear damage of glued laminated wood beams under bending loading due to low longitudinal shear strength, but also provides a reference for the structural study of wood-steel composite I-beams in beam units with large spans. The shear strength of the glued laminated timber I-beam obtained by using Rammer's formula has an error of 4.49% from the test. The research results also enable the tensile and compressive strength of I-beam timbers to be well developed.
Comments on this article