AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Experimental study on operating characteristics of a high capacity dual compensation chamber loop heat pipe

Haiyang QIN1Jingwei FU2Ruyi ZHANG1Li WANG1Lizhan BAI3( )
Xinxiang Aviation Industry (Group) Co.,Ltd.,Xinxiang 453003,China
The 29th Institute of China Electronics Technology Group Corporation,Chengdu 610036,China
School of Aeronautic Science and Engineering,Beihang University,Beijing 100191,China
Show Author Information

Abstract

The advanced fighter aircraft's onboard electronic equipment is developing towards high power, high integration, and miniaturization, which results in a continuous increase in heat generation and heat flux and poses a serious challenge to airborne thermal management. With a transport distance of 2.30 meters and ammonia as the working fluid, a high-power dual compensation chamber loop heat pipe(LHP) was created in response to the aforementioned specifications. A comprehensive and systematic experimental study on the dual compensation chamber loop heat pipe was conducted, mainly focusing on its startup characteristics, heat transfer capacity, and thermal resistance change. With a heat transfer capacity of over 900 W, the testing findings demonstrate that the dual compensation chamber loop heat pipe can successfully accomplish startup and run smoothly under a variety of evaporator attitudes, including horizontal, favorable, and unfavorable attitudes. The system thermal resistance of the dual compensation chamber loop heat pipe first rapidly decreases and then gradually increases with the increase of the heat load, and the minimum value is about 0.063 ℃/W. This work provides a new technological means and a feasible solution for efficient thermal management of future airborne systems.

CLC number: TB657.5;V228.3 Document code: A Article ID: 1001-5965(2026)07-2352-07

References

【1】
【1】
 
 
Journal of Beijing University of Aeronautics and Astronautics
Pages 2352-2358

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
QIN H, FU J, ZHANG R, et al. Experimental study on operating characteristics of a high capacity dual compensation chamber loop heat pipe. Journal of Beijing University of Aeronautics and Astronautics, 2026, 52(7): 2352-2358. https://doi.org/10.13700/j.bh.1001-5965.2024.0397

6

Views

0

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 05 June 2024
Published: 08 October 2024
© Journal of Beijing University of Aeronautics and Astronautics