AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Improved sliding-mode direct power control strategy for MMC-HVDC under asymmetrical grid state

Tianyi GUAN1,2, Yibo WANG1, Rui WANG1( ), Haiqiao ZHAO1, Wenjing ZHENG3, Qiuye SUN1
College of Information Science and Engineering,Northeastern University,Shenyang 110819,China
State Grid Liaoning Electric Power Co.,Ltd.,Shenyang Power Supply Company,Shenyang 110811,China
State Grid Liaoning Electric Power Co.,Ltd.,Marketing Service Center,Shenyang 110168,China
Show Author Information

Abstract

The modular multilevel converter based high voltage direct current (MMC-HVDC) is a dynamic power balancing system. The control system of MMC generally adopts a dual closed-loop vector control strategy based on the traditional instantaneous power model under an asymmetric grid state, which has a complex control structure and low control accuracy. This paper introduces a flexible instantaneous power model and establishes a general power equation with active power and new reactive power as control objects. In order to eliminate the twice grid-frequency ripples in both active and reactive power under asymmetric grid states, an enhanced sliding-mode MMC-HVDC direct power control strategy based on the new instantaneous power model is proposed. This approach combines the improved sliding-mode control method with the flexible instantaneous power model. Furthermore, it omits the inner-loop controller and power compensation terms while optimizing the control structure. According to simulation results, the suggested approach can more effectively take advantage of the benefits of the flexible instantaneous power model because it has superior dynamic responsiveness, control precision, and robustness under operating conditions including asymmetric grid state and parameter perturbation.

CLC number: TM46 Document code: A Article ID: 1001-5965(2025)05-1428-12

References

【1】
【1】
 
 
Journal of Beijing University of Aeronautics and Astronautics
Pages 1428-1439

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUAN T, WANG Y, WANG R, et al. Improved sliding-mode direct power control strategy for MMC-HVDC under asymmetrical grid state. Journal of Beijing University of Aeronautics and Astronautics, 2025, 51(5): 1428-1439. https://doi.org/10.13700/j.bh.1001-5965.2023.0277

965

Views

28

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 25 May 2023
Published: 06 December 2023
© Journal of Beijing University of Aeronautics and Astronautics