AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

In-orbit operation characteristics of BDS-3 spaceborne atomic clocks

Wenbin WANG1,2, Chengpan TANG1( ), Jianhua YANG1,2, Xiaogong HU1, Yueling CAO1, Shanshi ZHOU1
Shanghai Astronomical Observatory,Chinese Academy of Sciences,Shanghai 200030,China
University of Chinese Academy of Sciences,Beijing 100049,China
Show Author Information

Abstract

In order to evaluate in-orbit operation characteristics of BeiDou-3 Navigation Satellite System (BDS-3) spaceborne atomic clocks, the broadcast clock offset parameters and precise clock offset data released by the International GNSS Service (IGS) Analysis Center were used to analyze the satellite’s broadcast clock offsets, time-varying characteristics of broadcast clock speed, frequency accuracy, and frequency drift rate. The results indicate that the average error of clock offset parameters of the BDS-3 satellite is about 0.41 m, which is the key factor affecting the precision of the satellite space signal. Furthermore, BDS-3 broadcast clock speed parameters fluctuate frequently, so the spaceborne clocks’ high frequency stability has not been brought into full play. The frequency accuracy of BDS-3 spaceborne clocks is poor, but that of the hydrogen clock of the geostationary orbit (GEO) satellite is high. The frequency drift rate of the BDS-3 spaceborne rubidium clock is larger, resulting in too many frequency modulation times and affecting system availability. BDS-3 hydrogen clock has a lower frequency drift rate and higher long-term stability, which indicates advantages in on-board autonomous time-keeping.

CLC number: P228.1 Document code: A Article ID: 1001-5965(2025)05-1694-11

References

【1】
【1】
 
 
Journal of Beijing University of Aeronautics and Astronautics
Pages 1694-1704

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG W, TANG C, YANG J, et al. In-orbit operation characteristics of BDS-3 spaceborne atomic clocks. Journal of Beijing University of Aeronautics and Astronautics, 2025, 51(5): 1694-1704. https://doi.org/10.13700/j.bh.1001-5965.2023.0266

1154

Views

27

Downloads

0

Crossref

0

Scopus

1

CSCD

Received: 23 May 2023
Published: 04 August 2023
© Journal of Beijing University of Aeronautics and Astronautics