AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Parallel MRI reconstruction by using complex convolution and attention mechanism

Jizhong DUAN( ), Chen XIAO
Faculty of Information Engineering and Automation,Kunming University of Science and Technology,Kunming 650500,China
Show Author Information

Abstract

for the reconstruction of parallel magnetic resonance imaging, a deep complex attention network (DCANet) model is proposed. A data consistency layer is used to maintain acquired k-space data unchanged, and a cascade network is formed. Additionally, since magnetic resonance images of multiple coils differ, the proposed model also uses a channel-wise attention mechanism to focus on channels with more effective features. All of these techniques are used to replace the conventional method of convolving real and imaginary parts separately in complex convolution. Experiments are conducted on two different magnetic resonance imaging datasets with three different undersampling patterns. According to the experimental findings, the DCANet model performs better during reconstruction and achieves lower high-frequency error norm (HFEN) and greater peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). The DCANet model achieves average PSNR improvements of 4.52 dB, 2.30 dB and 1.21 dB over MRI cascaded channel-wise attention network (MICCAN), Deepcomplex and DONet models, respectively.

CLC number: TP391;R319 Document code: A Article ID: 1001-5965(2025)01-0085-09

References

【1】
【1】
 
 
Journal of Beijing University of Aeronautics and Astronautics
Pages 85-93

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
DUAN J, XIAO C. Parallel MRI reconstruction by using complex convolution and attention mechanism. Journal of Beijing University of Aeronautics and Astronautics, 2025, 51(1): 85-93. https://doi.org/10.13700/j.bh.1001-5965.2022.1005

638

Views

3

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 19 December 2022
Published: 22 March 2023
© Journal of Beijing University of Aeronautics and Astronautics