AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (15.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Study on Structural Optimization and Thermal Management Performance of Embedded Composite Cooling Plate Based on Wavy Channel

Yunxiang Cai1,2Qin Sun1,2( )Bobo Zhang1,2Xiaobin Gu2Yanjun Zhang2Kaijun Dong1,2
School of Energy Science and Technology, University of Science and Technology of China, Hefei, 230026, China
Guangdong Provincial Key Laboratory of Renewable Energy, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou, 510640, China
Show Author Information

Abstract

An efficient thermal-management system is crucial for the safe operation of lithium batteries. In this study, an embedded composite cooling plate integrating wavy flow channels with a phase-change material (PCM) and liquid cooling was designed for the thermal management of lithium batteries. From the perspective of recovering the latent heat of a thermally saturated PCM, an evaluation method was proposed to quantitatively analyze the latent heat recovery performances, pumping energy consumptions, and overall performances of different structural configurations. The optimal structural configuration was determined by comparing the overall performances. This configuration included a circular flow shape, circular cross-section, double channels, a cross-sectional area of 36 mm2, and a circular arc angle of 150°. The validity of the established numerical model was experimentally verified. Based on the optimal cooling plate structure, the heat generation of lithium batteries during 3 C rate operation was simulated using a surface heat source, and the effects of several delayed-start strategies for liquid cooling based on the PCM liquid-phase fraction on cooling performance were investigated. The results showed that the best temperature performance could be achieved by switching on the liquid cooling when the PCM liquid phase fraction reached 0.6, achieving a maximum temperature for the cooling plate of 38.32 ℃ and maximum temperature difference of 1.66 ℃, while decreasing the running time of the liquid cooling by 50.50% compared with that of the continuous mode.

CLC number: TB61+1; TQ026; TQ021.3 Document code: A Article ID: 0253-4339(2025)06-0045-11

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 45-55

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Cai Y, Sun Q, Zhang B, et al. Study on Structural Optimization and Thermal Management Performance of Embedded Composite Cooling Plate Based on Wavy Channel. Journal of Refrigeration, 2025, 46(6): 45-55. https://doi.org/10.12465/j.issn.0253-4339.2025.06.045

138

Views

1

Downloads

0

Crossref

0

CSCD

Received: 18 June 2024
Revised: 11 September 2024
Accepted: 26 September 2024
Published: 16 December 2025
© 2025 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).