AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Design Calculation and Performance Test of the Evaporator-Condenser for Direct Heat Transfer between Heat Pipe and Heat Pump

Weijie Lin1,2,3,4Jiwen Cen1,2,3,4( )Hassan Abdullah1,2,3,4Fangming Jiang1,2,3,4
School of Energy Science and Engineering, University of Science and Technology of China, Guangzhou, 510640, China
Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences (CAS), Guangzhou, 510640, China
CAS Key Laboratory of Renewable Energy, Chinese Academy of Sciences (CAS), Guangzhou, 510640, China
Guangdong Provincial Key Laboratory of Renewable Energy, Guangzhou, 510640, China
Show Author Information

Abstract

The combination of a super-long gravity heat pipe and a heat pump system for harvesting deep geothermal heat has the advantages of low cost, high efficiency, and no groundwater contamination. Direct heat exchange between the evaporator of the heat pump system and the condenser of the gravity heat pipe can simplify the heat exchange process and improve the heating efficiency of the system. Therefore, a U-shaped evaporator-condenser was developed, and its heat transfer performance was studied by building an experimental platform combining a heat pump and a heat pipe. Notably, the heat transfer coefficient of the U-shaped evaporator-condenser reached 2037.92 W/(m2·℃) when the working fluid on the heat pump side passed through the tube. Based on the homogeneous flow model, a one-dimensional steady-state evaporator-condenser heat transfer model was established by integrating the mass, energy, and momentum conservation equations with empirical formulas for condensation outside the tube and boiling heat transfer inside the tube. Using Python, the simulation results were compared with experimental data. Notably, the average deviation of the heat transfer in the evaporator-condenser was 18.91%, confirming the accuracy of the model and providing a theoretical calculation method for designing an efficient evaporator-condenser.

CLC number: TB61+1; TB657.5 Document code: A Article ID: 0253-4339(2025)05-0105-10

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 105-114

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lin W, Cen J, Abdullah H, et al. Design Calculation and Performance Test of the Evaporator-Condenser for Direct Heat Transfer between Heat Pipe and Heat Pump. Journal of Refrigeration, 2025, 46(5): 105-114. https://doi.org/10.12465/j.issn.0253-4339.2025.05.105

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 17 April 2024
Revised: 24 August 2024
Accepted: 26 August 2024
Published: 16 October 2025
© 2025 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).