Research to Optimize the Refrigerant Charge of the Natural Refrigerants R1270 and R290 in Heat-Pump Water Heaters and Their Performance

Fujun Ju( )Lihao HouQinglei LiuHaoran WangChengjie XiaoXiaowei Fan
School of Smart Energy and Environment, Zhongyuan University of Technology, Zhengzhou, 450007, China
Show Author Information

Abstract

R1270 and R290 are alternative refrigerants with great potential. In this study, the influence of the refrigerant charge on the performance of the heat-pump water heater with R1270 and R290, the temperature distribution of the heat transfer fluids in the condenser, and the feasibility of replacing R22 with natural refrigerants were investigated. The results indicate that the refrigerant charge has a considerable influence on the cycle performance and the temperature distribution of the heat-transfer fluids in both systems. At the same optimal charge (0.90 kg), the R1270 and R290 systems achieved a maximum coefficient of performance (COP) of 4.443 and 4.317, respectively. At different refrigerant charges, two heat transfer pinch points and two maximum heat transfer temperature differences occurred in the condensers of both systems, and the locations of the first pinch point and the second maximum temperature difference point showed similar migrations with changes in refrigerant charge. Compared with the R22 system, both the R1270 and R290 systems, at optimal charge, achieved significantly better COP and discharge temperatures, exhibited relatively equivalent discharge pressures, and their heating capacities increased by 7.05% and decreased by 10.65%, respectively. Hence, R1270 can be preferred over R290 for replacing R22 in a heat-pump water heater.

CLC number: TB64; TM925.32; TU822.2 Document code: A Article ID: 0253-4339(2025)05-0069-08

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 69-76

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ju F, Hou L, Liu Q, et al. Research to Optimize the Refrigerant Charge of the Natural Refrigerants R1270 and R290 in Heat-Pump Water Heaters and Their Performance. Journal of Refrigeration, 2025, 46(5): 69-76. https://doi.org/10.12465/j.issn.0253-4339.2025.05.069

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 29 March 2024
Revised: 05 August 2024
Accepted: 06 August 2024
Published: 16 October 2025
© 2025 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).