AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Performance of Helium-Valved Linear Compressor Motor for Space Use

Kangjun Liu1,2Xinquan Sha2Zicheng Li2Qi Huang2,3Kongkuai Ying2Lei Ding2( )Shaoshuai Liu2,3Zhenhua Jiang2,3Yinong Wu1,2,3
School of Information Science and Technology, ShanghaiTech University, Shanghai, 201210, China
Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, 200083, China
University of Chinese Academy of Sciences, Beijing, 100049, China
Show Author Information

Abstract

As the driving component of a valved linear compressor, the matching relationship between the motor force and gas force directly affects the performance of the compressor. A simulation model of the linear motor was established based on the equivalent gas-force model. In addition, a test bench for the valved linear compressor was constructed to analyze both the simulation and experimental results under various working conditions. This study aimed to investigate the performance of a compressor across different operating scenarios while verifying the reliability of gas force linearization. When the inflation pressure and piston pressure were 0.2 MPa and 5 mm, respectively, the resonance frequency of the experiment and simulation was 50 Hz, and the motor efficiency was 84.3%. The maximum relative errors of the input work, voltage, current, and motor efficiency were 25.8%, 21.7%, 22.7%, and 13.5%, respectively. This indicates that the motor efficiency of the compressor is related to its resonance frequency and that the motor efficiency of the compressor is the highest when the resonance frequency is consistent with the operating frequency. The simulation model of the linear motor is reliable, and the calculation results for the gas load are relatively accurate.

CLC number: TB61+1; TB652 Document code: A Article ID: 0253-4339(2025)03-0104-09

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 104-112

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu K, Sha X, Li Z, et al. Performance of Helium-Valved Linear Compressor Motor for Space Use. Journal of Refrigeration, 2025, 46(3): 104-112. https://doi.org/10.12465/j.issn.0253-4339.2025.03.104

69

Views

0

Downloads

0

Crossref

0

CSCD

Received: 21 December 2023
Revised: 29 January 2024
Accepted: 15 April 2024
Published: 16 June 2025
© 2025 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).