Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOl and etc.
As the power density of lithium-ion batteries continues to increase and high-power fast-charging technologies emerge, the development of battery thermal management systems has become an important and challenging area of research. In this study, a direct-cooling thermal management system for multi-box battery packs using roll-bond cold plates was presented, and the performance of the system was experimentally investigated under different operating conditions. The experimental results show that at a charging rate of 0.5 C and a compressor speed of 2400 r/min, the average coefficient of performance (COP) of the system can reach 5.83, the maximum dimensionless loss coefficient of the cold plate is 6.27%, and the maximum temperature difference between the cold plates is 1.90 ℃. Notably, the temperature difference between the plates escalates with increasing compressor speed and the thermal load on the cold plate, reaching a maximum value of 3.99 ℃ during the tests. Concurrently, the COP of the system showed a decreasing trend with the compressor speed, reaching a maximum value of 7.41 throughout the duration of the experiments.
This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).
Comments on this article