Discover the SciOpen Platform and Achieve Your Research Goals with Ease.
Search articles, authors, keywords, DOl and etc.
A compressor outlet tube is a transmission component of sound power, and its sound power loss directly affects the performance of pulse tube cryocoolers. Flexible bellows can adjust the relative positions of compressors and cold fingers in applications compared with traditional rigid smooth tubes. This study analyzed the flow characteristics of two types of connected pipes by simulation, and the influence of different types of connected pipes on the performance of the entire machine was verified experimentally to determine the influence of flexible bellows on the cryocooler. The simulation results demonstrated that mixed flow appears at the ripple of the bellows, resulting in greater resistance loss, when compared with a rigid smooth pipe. Under the same inlet parameters, the outlet mass flow and pressure amplitude were lower, and the sound power loss was greater. The experimental results demonstrated that the input power required by the bellows was higher when the cooling capacity was the same. When the cooling temperature was 37.5 K and the cooling capacity was 0.5 Wthe input power of bellows and smooth tubes was 119 W and 112 W, respectively; when the cooling capacity was 3.0 W, the input power of bellows and smooth tubes was 279 W and 259 W, respectively.
This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).