AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (10 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Multi-Energy Complementary Absorption Heat Pump Applied for Combined Cooling and Heating over a Wide Temperature Range

Ding Lu1,2( )Zijian Liu1,2Tao Shen1,2Rundong Chen1,2Maoqiong Gong1,2
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
University of Chinese Academy of Sciences, Beijing, 100049, China
Show Author Information

Abstract

Achieving low-carbon combined cooling and heating supply in distributed areas away from centralized cooling and heating networks is highly significant in the context of carbon neutrality. This study proposes a combined cooling and heating system based on an absorption heat pump, which uses a variety of clean and renewable energies, such as solar heat, geothermal, waste heat, biomass, and air-source energy, to achieve the combined cooling and heating in a wide temperature range from -20 ℃ to 90 ℃. Such systems are suitable for distributed areas, such as villages, cities, and industrial parks. The system model was constructed based on Aspen, and a prototype was developed. The prototype uses a vacuum tube collector to capture solar thermal energy and introduces natural gas as a supplementary heat source to balance fluctuations of solar energy. Multiple sets of indoor heating and cooling terminals can be driven through medium circulation and valve switching using a single set of absorption heat pumps and outdoor units. The environmental test of the prototype was performed in Jinan, and the solar thermal ratio reached 35% during the testing period. An all-weather stable energy supply was achieved by proportional control of natural gas. Moreover, a wide range of concentration adjustments was achieved by controlling the liquid level in the solution tank, enabling efficient system operation in a wider temperature range. The coefficient of performance(COP) of cooling reached 0.30-0.43 at-20 ℃ and 0.70-0.78 at 7 ℃, with cooling water temperatures varying from 30 ℃ to 20 ℃; the COP of heating reached 1.40-1.90 at 45 ℃ and 1.35-1.56 at 80 ℃, with evaporation temperature varying from -15 ℃ to 20 ℃. The study results demonstrated that introducing solar thermal energy and ambient energy recovery increased the fraction of renewable energy in the system to over 50%. Compared with the traditional method of gas furnace plus air conditioning, the annual operating cost and carbon emissions of the proposed system were reduced by over 54.3% and 44%, respectively, which has significant application potential.

CLC number: TB61+1;TQ051.5;TU83 Document code: A Article ID: 0253-4339(2025)01-0024-08

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 24-31

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lu D, Liu Z, Shen T, et al. Multi-Energy Complementary Absorption Heat Pump Applied for Combined Cooling and Heating over a Wide Temperature Range. Journal of Refrigeration, 2025, 46(1): 24-31. https://doi.org/10.12465/j.issn.0253-4339.2025.01.024

1

Views

0

Downloads

0

Crossref

0

CSCD

Received: 26 February 2024
Revised: 14 March 2024
Accepted: 15 March 2024
Published: 16 February 2025
© 2025 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).