Load Characteristics Analysis of Water-Source Heat Pump System for Harvesting Waste Heat from Small Data Centers

Feng Zhou( )Yu SongGuoyuan MaXianghui Yan
Department of Refrigeration and Cryogenic Engineering, Beijing University of Technology, Beijing, 100124, China
Show Author Information

Abstract

The power usage limit becomes lower with the green development of data centers. The small liquid cooling device is emerging as a new cooling option for small data centers with high energy density, which helps recover the waste heat. In this paper, the energy efficiency characteristics of three types of water-source heat pump systems under different surplus heat conditions are compared and analyzed in the surplus heat load range of small data centers. The energy efficiency of the water-source heat pump system is distributed at 5-7, 5-6, and 4.5-6.5 on the source side, transmission and distribution side, and user side, respectively. When the user-side heat load is retained at 0 kW to 1750 kW and 2500 kW to 3200 kW, the energy efficiency of the source-side enhanced water-source heat pump system is highest. When the user-side heating load demand is 1750 kW to 2500 kW, the energy efficiency of the source-side enhanced water-source heat pump system is near that of the transmission and distribution-side enhanced water-source heat pump system. Finally, the coupling matching formula QN=kQS is obtained between the user-side heat load demand and data center surplus heat load, in which k ranges from 1.1962 to 1.3642.

CLC number: TB61+1; TB657.5 Document code: A Article ID: 0253-4339(2024)06-0063-12

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 63-74

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhou F, Song Y, Ma G, et al. Load Characteristics Analysis of Water-Source Heat Pump System for Harvesting Waste Heat from Small Data Centers. Journal of Refrigeration, 2024, 45(6): 63-74. https://doi.org/10.12465/j.issn.0253-4339.2024.06.063

2

Views

0

Downloads

0

Crossref

0

CSCD

Received: 23 August 2023
Revised: 31 October 2023
Accepted: 27 November 2023
Published: 16 December 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).