AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (7.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Noise Reduction Design of Electronic Expansion Valve Based on Structural Optimization of Flow Pattern Regulator

Yantao Liu1Tianjie Zhu2Feilong Zhan2Shaohua Zhou2Guoliang Ding2( )Jiabo Ji1Zheming Gao1
GD Midea Refrigeration Equipment Co., Ltd., Foshan, 528311, China
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
Show Author Information

Abstract

Electronic expansion valves(EEVs) in air conditioner systems may induce serious flow noise when the refrigerant flows into them with unstable two-phase flow patterns. The addition of a flow pattern regulator in the flow path of an EEV is expected to stabilize the refrigerant flow pattern, thereby reducing flow noise. Therefore, determining the influence of flow pattern regulators on the flow noise of EEVs is essential for optimizing their structural parameters. In this study, a method for flow pattern simulation was verified through experiments. Then, the influence of the structural parameters of the flow pattern regulator, including the hole interval, thickness, and hole diameter, on the flow noise of the EEV under the typical unstable slug flow pattern was determined. Finally, the structure of the flow pattern regulator was optimized by reasonably combining the parameters to minimize the flow noise of the EEV. The results showed that the flow noise increased as the hole interval increased, whereas it initially decreased and subsequently increased as the thickness or hole diameter increased. The hole diameter is the most important factor affecting flow pattern regulation, and flow noise can be significantly reduced by appropriately designing the hole diameter. Under the working conditions of this study, noise was reduced by 6.88 dB.

CLC number: TB657.2;TB53 Document code: A Article ID: 0253-4339(2024)05-0114-09

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 114-122

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu Y, Zhu T, Zhan F, et al. Noise Reduction Design of Electronic Expansion Valve Based on Structural Optimization of Flow Pattern Regulator. Journal of Refrigeration, 2024, 45(5): 114-122. https://doi.org/10.12465/j.issn.0253-4339.2024.05.114

7

Views

0

Downloads

0

Crossref

0

CSCD

Received: 11 July 2023
Revised: 29 August 2023
Accepted: 26 October 2023
Published: 16 October 2024
© 2024 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).