AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Study of the Performance-Economic-Environmental Impact of Replacing R404A with R448A in Refrigeration Systems

Peicheng Ma1Xiaohai Zheng2Yongqiang Wang2Zilong Wang1( )Wenjing Gao1Hua Zhang1
College of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
Karamay Carbon Neutral Network Technology Co., Ltd., Karamay, 834000, China
Show Author Information

Abstract

R404A is a widely used medium-temperature refrigerant in low-and medium-temperature refrigeration systems because of its excellent efficiency and ozone-friendly properties. However, its high Global Warming Potential (GWP=3922) has led to its scheduled phase-out by 2030. R448A has emerged as a key alternative, offering superior thermophysical properties and a significantly lower GWP. This study investigated a refrigeration system in high-and low-temperature test chambers to explore the operating conditions for the case of R404A replaced by R448A. The results showed that the cooling capacity and coefficient of performance (COP) of both systems initially increased and then decreased with increasing refrigerant charge. The optimal charge for R448A was approximately 9.3% higher than that for R404A, and its cooling capacity and COP improved by over 17%. At the same evaporation temperature, the R448A system was less sensitive to ambient temperature fluctuations. A 10 ℃ increase in ambient temperature resulted in a 16.9% decrease in cooling capacity for R404A, whereas R448A only experienced an 8.6% decrease. Additionally, the maximum COP of the R448A system was approximately 9.9% higher than that of R404A. The return on investment for R448A is approximately one year, and as the system's life cycle progresses, the total annualized cost (TAC) of R448A becomes lower than that of R404A, with annual savings ranging from 0.6% to 6.6%. Replacing R404A with R448A can reduce total carbon emissions by over 32%, with approximately 27% of this reduction attributed to refrigerant leakage during operation and end-of-life recycling.

CLC number: TB61+1; TB657.3 Document code: A Article ID: 0253-4339(2026)04-0113-11

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 113-123

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ma P, Zheng X, Wang Y, et al. Study of the Performance-Economic-Environmental Impact of Replacing R404A with R448A in Refrigeration Systems. Journal of Refrigeration, 2026, 47(4): 113-123. https://doi.org/10.12465/issn.0253-4339.20250502002

3

Views

0

Downloads

0

Crossref

0

CSCD

Received: 02 May 2025
Revised: 08 June 2025
Accepted: 01 August 2025
Published: 16 August 2026
© 2026 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).