Review of the Non-Uniform Frosting/Defrosting Characteristics of Air-Cooled Refrigerator Evaporators

Xudong HanXinyi ZhangHan WangRijing ZhaoDong Huang( )
School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
Show Author Information

Abstract

Non-uniform frost accumulation on evaporator coils is a significant feature in air-cooled refrigerators. It is also one of the important causative factors leading to evaporator performance degradation. This paper reviews related research in three distinct areas: non-uniform frost characteristics of air-cooled refrigerator evaporators, defrost optimization based on these characteristics, and frost detection optimization. A concise introduction is provided into the formation mechanism of non-uniform frost on air-cooled refrigerator evaporators, the influencing factors, and their impact on refrigerator performance. Frost-heat matching defrosting and frost suppression strategies for the evaporators of air-cooled refrigerators are systematically summarized. The complex challenges and solutions of direct and indirect frost detection techniques under non-uniform frost conditions are analyzed. The performance degradation of air-cooled refrigerator evaporators is summarized and discussed. Finally, this study identifies shortcomings in the research field of non-uniform frost on aircooled refrigerator evaporators and proposes potential future development directions. This study aims to provide a framework for the efficient operation and energy-saving optimization of air-cooled refrigerators.

CLC number: TB61+1; TB657.4 Document code: A Article ID: 0253-4339(2026)03-0053-14

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 53-66

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Han X, Zhang X, Wang H, et al. Review of the Non-Uniform Frosting/Defrosting Characteristics of Air-Cooled Refrigerator Evaporators. Journal of Refrigeration, 2026, 47(3): 53-66. https://doi.org/10.12465/issn.0253-4339.20250326001

2

Views

0

Downloads

0

Crossref

0

CSCD

Received: 26 March 2025
Revised: 20 April 2025
Accepted: 26 May 2025
Published: 16 June 2026
© 2026 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).