Experimental Study on the Performance of Waterless Floor Heating and Hot Water Dual Supply Air-Source Heat Pump System

Jianhui NiuZelong AnChenyang ZhangYuzhou WuYujin Zhang( )
Hebei Renewable Energy Heating Engineering Technology Center, Hebei University of Architecture, Zhangjiakou, 075000, China
Show Author Information

Abstract

A new type of air-source heat pump system is proposed, combining domestic hot water and waterless floor heating that is achieved by the direct condensation of the refrigerant in buried pipes. The high-temperature refrigerant is exchanged in the wrapped coil water heater to produce domestic hot water. The prototype was assembled and tested in three modes: standalone floor heating, dual supply, and standalone domestic hot water. The experimental results show that in all three cases, the surface temperature of the floor was maintained between 25 ℃ and 33 ℃, and the air temperature was maintained between 18 ℃ and 22 ℃. Due to the heat storage effect of the capillary floor, the air temperature in the room remained above 18 ℃ within 113-245 min after terminating the system. At an ambient temperature of -5 ℃, after 572.3 min, the water temperature of the water heater rose to 45 ℃. The minimum system heating capacity and energy efficiency ratio (EER) can reach 2.70 kW and 3.55, respectively.

CLC number: TB61+1; TU832.2 Document code: A Article ID: 0253-4339(2026)03-0142-08

References

【1】
【1】
 
 
Journal of Refrigeration
Pages 142-149

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Niu J, An Z, Zhang C, et al. Experimental Study on the Performance of Waterless Floor Heating and Hot Water Dual Supply Air-Source Heat Pump System. Journal of Refrigeration, 2026, 47(3): 142-149. https://doi.org/10.12465/issn.0253-4339.20250301003

2

Views

0

Downloads

0

Crossref

0

CSCD

Received: 01 March 2025
Revised: 31 March 2025
Accepted: 26 May 2025
Published: 16 June 2026
© 2026 The Editorial Office of Journal of Refrigeration

This is an open access article under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0, http://creativecommons.org/licenses/by/4.0/).