Seismic Response Analysis of Cable-stayed Bridges Considering Material Nonlinearity and Local Cable Vibrations

Qu WANG1,2, Junjie LIU1, Dingxi CAI3, Yingxiong WU1, Qingxiong WU1,4( ), Zhichao CAI1
College of Civil Engineering, Fuzhou University, Fuzhou 350108, China
Fujian Provincial Key Laboratory on Multi-disasters Prevention and Mitigation in Civil Engineering, Fuzhou 350108, China
Fuzhou Shuangfu Expressway Co., Ltd., Fuzhou 350011, China
Key Laboratory of Civil Engineering, Fujian Province University, Fuzhou 350108, China
Show Author Information

Abstract

Objective

A cable-stayed bridge is a structure in which the deck is supported by cables extending directly from one or more towers to the deck. Nonlinear material behavior and local vibrations of the stay cables may amplify the bridge's seismic response, potentially compromising structural safety and causing significant economic and social consequences. In this study, we quantify the effects of nonlinear cable vibrations on the dynamic response and principal vibration modes of the main girder-tower system by accounting for the interactions among cable material nonlinearity, local cable vibrations, and the nonlinear dynamics of the girder-tower system.

Methods

Nonlinearity in structural analysis generally refers to geometric nonlinearity and material nonlinearity. To account for the stress-strain relationships of steel and concrete in reinforced concrete (RC) sections, we model the RC cross sections using fiber-based beam elements. Each section is divided into multiple concrete and steel fibers, allowing material nonlinearity to be captured. In contrast, stay cables are flexible components that adopt a catenary shape under self-weight and axial force. Cable sag due to self-weight affects the cable stiffness. Including self-weight in dynamic analyses increases computational complexity and may introduce substantial errors. Therefore, self-weight is excluded from the local vibration analysis of the cables, such that the element restoring force depends only on nodal displacements and the element axial force. Traditionally, the one-element cable system (OECS) has been used to model stay cables in finite-element analyses, with each cable represented by a single element and its sag-induced nonlinearity approximated using an equivalent elastic modulus. However, to simulate the simultaneous local vibrations of the main girder, tower, and stay cables, we adopt a multi-element cable system (MECS), in which each stay cable is discretized into multiple elements. Using a (115+165) m single-tower, single-cable, plane-asymmetric cable-stayed bridge as a case study, we develop a finite-element model using our in-house program NL Beam 3D. The model incorporates cable segmentation and material nonlinearity, and its results are compared with those obtained using a conventional approximate method. Finally, we investigate the dynamic responses of the main girder, tower, and stay cables under moderate and strong earthquake excitations, accounting for both geometric and material nonlinearities.

Results and Discussions

Compared with the MIDAS Civil model, the key frequencies of the first nine modes calculated using the OECS model agree closely with those obtained from MID AS Civil, except for the first mode. The initial axial force significantly influences the lower-order frequencies. We then developed a MECS model using our in-house program NL_Beam_3D to account for material nonlinearity and local cable vibrations. The differences in key frequencies between the MECS and conventional OECS models are less than 1.2%. Under moderate and strong earthquake excitations, certain stay cables exhibit large-amplitude nonlinear vibrations that affect the main girder and tower. For example, under moderate earthquake excitation, cables M4 and M14 exhibit noticeable local vibrations, with vertical amplitudes of -1.201 and 1.256 m, respectively, approximately two to three times those of the corresponding cables modeled without local vibration. Correspondingly, the axial force in cable M14 predicted by the MECS model is 6.49% higher than that predicted by the OECS model, indicating that local cable vibrations can substantially increase cable forces. Under strong earthquake excitation, nonlinear cable vibrations become more pronounced, with cables S16, M14, and M15 all exhibiting large-amplitude vibrations. The vertical amplitudes of cable M15 cable reach-1.936 and 2.130 m, representing increases of approximately 173.78% and 143.52%, respectively, relative to the corresponding amplitudes under moderate earthquake excitation. Meanwhile, the difference in the force of cable M14 increases from 6.49% under moderate earthquake excitation to 13.76% under strong earthquake excitation. These results indicate that increasing seismic intensity amplifies local cable vibrations and their effects on cable forces. The influence of nonlinear cable vibrations on the displacement and internal force responses of the main girder increases with seismic intensity. Under moderate earthquake excitation, the difference in vertical displacement at the midspan (2P-3P) girder section between the MECS and OECS models is approximately 9.34%. Under strong earthquake excitation, this difference increases to 18.23%, indicating that local cable vibrations have a greater influence on girder deformation under stronger seismic excitation. Regarding the internal forces in the main girder, the out-of-plane bending moment is the most affected by local cable vibrations. At the 2P-3P midspan section, the difference in out-of-plane bending moment between the MECS and OECS models reaches 15.76% under strong earthquake excitation, substantially exceeding the corresponding differences in axial force and in-plane bending moment. In contrast, the influence of nonlinear cable vibrations on the main tower response is relatively limited. Under moderate and strong earthquake excitation, the differences in longitudinal displacement at the tower 's cable-anchorage zone between the MECS and OECS models range from 3.29% to 8.06% and from 3.09% to 7.50%, respectively. Regarding the internal forces in the main tower, the differences in axial force and in-plane bending moment remain within approximately 10%. These results indicate that, although local cable vibrations have a limited influence on the overall mechanical response of the tower, they still affect its local dynamic response.

Conclusions

The proposed MECS method, which discretizes stay cables into multiple elements and incorporates material nonlinearity enables a more accurate analysis of the dynamic coupling between the stay cables and the main girder-tower system. Neglecting local nonlinear cable vibrations in seismic analyses may lead to substantial underestimation of critical response quantities, including cable forces, girder displacements, and out-of-plane bending moments, particularly under strong earthquake excitation. Therefore, the MECS method is recommended for the seismic design and safety assessment of cable-stayed bridges.

CLC number: U448.27 Document code: A Article ID: 2096-3246(2026)06-0244-15

References

【1】
【1】
 
 
Advanced Engineering Sciences
Pages 244-258

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG Q, LIU J, CAI D, et al. Seismic Response Analysis of Cable-stayed Bridges Considering Material Nonlinearity and Local Cable Vibrations. Advanced Engineering Sciences, 2026, 58(6): 244-258. https://doi.org/10.12454/j.jsuese.202500806

6

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 20 October 2025
Revised: 27 November 2025
Published: 02 December 2025
© Editorial Department of Journal of Sichuan University (Engineering Science Edition).

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).