The widespread integration of power electronic devices contributes to a continuous decline in the inertia levels of modern power systems. Therefore, the accurate and rapid assessment of regional equivalent inertia is essential for developing refined regulation strategies and maintaining frequency stability. In this study, we introduce a novel method for rapidly assessing regional system inertia based on frequency prediction errors.
Power and frequency data within a target region were collected through a wide-area measurement system and converted into equivalent representations. During this equivalence process, regional power was represented by the aggregate power output of all internal generators, whereas regional frequency was characterized by the equivalent center-of-inertia frequency. The raw phasor measurement unit (PMU) data were preprocessed using an adaptive least mean squares (LMS) filtering algorithm to address the practical issue of measurement noise from commercial PMUs. The LMS algorithm was employed to adjust filter weights adaptively, which minimized the mean square error between the output signal and the desired response and effectively suppressed noise. In addition, by deriving a frequency prediction error formula, the regional inertia assessment problem was transformed into a single-variable root-finding problem, in which the objective was to determine the inertia value that reduced the error between the predicted and measured frequencies to zero. A collaborative estimation algorithm that combined binary search with error feedback was proposed. The core of this algorithm involved the use of 100 consecutive data points within a 1 s time window following a system disturbance for global optimization. Through iterative optimization of a global equivalent inertia variable using binary search, the optimal inertia value was determined in a single process, which effectively addressed the noise sensitivity issues associated with traditional point-by-point calculation methods. The performance of the proposed method was rigorously validated through multi-scenario simulation tests conducted on a modified IEEE 39-bus system in the DIgSILENT PowerFactory environment and through actual operational data from a provincial power grid using the PSASP platform. The test conditions included various disturbance locations, different levels of power shortage, and systems with high penetration levels of renewable energy sources.
Simulation results obtained from the IEEE 39-bus system, with and without integrated renewable generation, demonstrated the effectiveness of the proposed method (Method 1). Its performance was compared to that of a direct solving method (Method 2) and an autoregressive moving average with exogenous inputs model-based method (Method 3). In the scenario without renewable energy, the mean estimation errors for the three methods were 1.41%, 2.41%, and 1.61%, respectively, with corresponding computation times of 0.015 s, 0.025 s, and 0.146 s. Under the scenario with 33.23% renewable energy penetration, the mean errors were 1.53%, 3.16%, and 6.71%, with corresponding solution times of 0.014 s, 0.026 s, and 0.141 s. These results indicated that the proposed method maintained high estimation accuracy while achieving significantly faster solution speeds. A scenario with 52.6% renewable energy penetration was examined, in which the relative errors for regional inertia assessment were 0.31%, −1.88%, 0.12%, and −2.56%, which confirmed the robustness of the method and further assessed its adaptability to systems with high renewable energy penetration. Investigations into the effects of data window length and disturbance moment identification revealed that a data window of approximately 1 s (100 sampling points) provided an optimal balance between estimation accuracy and computational speed. The algorithm exhibited low sensitivity to deviations in the initial moment, which enhanced its practical applicability by mitigating the effects of data synchronization errors in real-world engineering applications. Four distinct disturbance scenarios were established for testing: In Scenario 1, a 50% load step (an increase of 103 MW) was applied at Bus 28 at t = 1 s. In Scenario 2, the load at Bus 26 was disconnected (a reduction of 139 MW) at t = 1 s. In Scenario 3, a 5% load step (an increase of 55.2 MW) was applied at Bus 39 at t = 1 s. In Scenario 4, a 100% load step (an increase of 320 MW) was applied at Bus 15 at t = 1 s. The average deviation between the maximum and minimum estimated inertia values across the four disturbance scenarios was 0.18 s, which corresponded to 3.98% of the system’s equivalent inertia (4.43 s). In addition, under six different operating conditions, the estimation error for the system’s time-varying inertia remained within 2%. These findings demonstrated the strong adaptability of the method to different scenarios, operating conditions, and disturbance magnitudes. Finally, simulation tests were conducted using actual data from a provincial power grid in China. DC blocking and load disturbances were established as large- and small-disturbance scenarios, respectively. The results demonstrated that, under both conditions, the relative error in equivalent inertia estimation across all regions remained below 7%, with most errors below 3%. The computation time for all regional assessments across different scenarios consistently remained below 0.03 s, which fully satisfied the computational speed and accuracy requirements for online power system analysis and evaluation.
The proposed method demonstrated high effectiveness in regional inertia estimation across various scenarios, operating conditions, and disturbance scales. It exhibited considerable advantages in estimation accuracy, computational efficiency, and practical engineering applicability. We provide a reliable and efficient technical approach for online monitoring of power system inertia, supporting the secure and stable operation of power grids with increasingly high proportions of power electronic devices.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Comments on this article