AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Open Access

Research on the measurement of sow body temperature based on infrared thermography and linear regression fitting

Haonan TianJingyi HuaShaoshuai ZhangLongshen Liu( )
College of Artificial Intelligence, Nanjing Agricultural University, Nanjing 210031, China
Show Author Information

Abstract

Body temperature is one of the most important indicators of disease diagnosis in pigs. In order to reduce the manpower and material resources used in the measurement of traditional pigs' temperature methods and decrease the risk of pigs' stress and cross-infection between humans and pigs, the infrared thermal imager (Fluke Ti27) was used to acquire images of sows infrared heat radiation. The deep learning target detection network YOLOv3 was used to train and predict the dataset to accurately identify and locate the ear root of sow. The ear root part of the sow was selected as the best measurement part and with the temperature information of the ear root part in the thermal radiation picture obtained by the Fluke software (Fluke Connect SmartView), the relationships between the sow body temperature and the ambient temperature, the ambient humidity, the light intensity, the infrared temperature of the ear root were analyzed so that the multiple linear regression model with sow body temperature as the dependent variable and other variables as independent variables was established and the multiple linear regression function was used to optimally fit the sow body temperature. Using this model to estimate the data of the test set, the results showed that: under different environmental conditions, the maximum error between the fitted pig body temperature and the actual pig body temperature was 3.06%, and the average absolute error was 1.41%. The body temperature fitting is accurate, and the fitting error basically meets the pig breeding industry requirements. This method can be used as a non-contact measurement of pig body temperature in pig production, which improves the accuracy and efficiency of temperature measurement and has a good prospect.

CLC number: TP391.41 Document code: A Article ID: 2096-7217(2023)01-0036-06

References

【1】
【1】
 
 
Journal of Intelligent Agricultural Mechanization
Pages 36-41

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Tian H, Hua J, Zhang S, et al. Research on the measurement of sow body temperature based on infrared thermography and linear regression fitting. Journal of Intelligent Agricultural Mechanization, 2023, 4(1): 36-41. https://doi.org/10.12398/j.issn.2096-7217.2023.01.004

279

Views

2

Downloads

0

Crossref

Received: 05 September 2022
Revised: 05 January 2023
Published: 15 February 2023
© Journal of Intelligent Agricultural Mechanization (2023)

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)