AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Standards for the Application of Hemodynamic Monitoring Technology in Critical Care

Hua ZHAO1Hongmin ZHANG2Xin DING1Huan CHEN1Jun DUAN3Wei DU1Bo TANG1Yuankai ZHOU1Dongkai LI1Xinchen WANG1Cui WANG4Gaosheng ZHOU5Xiaoting WANG1( )
Department of Critical Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
Department of Health Care Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
Department of Critical Care Medicine, China-Japan Friendship Hospital, Beijing 100029, China
The First Affiliated Hospital of Anhui Medical University, Hefei 230022, China
Department of Critical Care Medicine, The First College of Clinical Medical Science, China Three Gorges University (Yichang Central People's Hospital), Yichang, Hubei 443000, China
Show Author Information

Abstract

With the rapid advancement of hemodynamic indices and monitoring technologies, their classification methods and application processes have become increasingly complex. Currently, no unified standard hasbeen established, making it difficult to fully meet the clinical requirements for hemodynamic management. To assist in hemodynamic monitoring assessment and therapeutic decision-making in critically ill patients, the Critical Hemodynamic Therapy Collaborative Group, in conjunction with the Critical Ultrasound Study Group, has jointly developed the Standard for the Application of Hemodynamic Monitoring Techniques in Critical Care. The first part of this standard systematically categorizes hemodynamic indicators into flow indicators, pressure and its derivative indicators, and tissue perfusion indicators, while elaborating on the clinical application of each. The second part establishes a standardized clinical implementation pathway for hemodynamic monitoring. It proposes a tiered monitoring strategy-comprising basic, advanced, indication-specific, and special scenario monitoring-tailored to different clinical settings. It emphasizes the central role of critical care ultrasound across all levels of monitoring and establishes hemodynamic assessment standards for organs such as the brain, kidneys, and gastrointestinal tract. This standard aims to provide a unified framework for clinical practice, teaching, training, and research in critical care medicine, thereby promoting standardized development within the discipline.

CLC number: R459.7 Document code: A Article ID: 1674-9081(2026)01-0073-13

References

【1】
【1】
 
 
Medical Journal of Peking Union Medical College Hospital
Pages 73-85

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHAO H, ZHANG H, DING X, et al. Standards for the Application of Hemodynamic Monitoring Technology in Critical Care. Medical Journal of Peking Union Medical College Hospital, 2026, 17(1): 73-85. https://doi.org/10.12290/xhyxzz.2025-1204

1368

Views

15

Downloads

0

Crossref

0

Scopus

0

CSCD

Received: 19 November 2025
Accepted: 09 January 2026
Published: 30 January 2026
© 2026 Medical Journal of Peking Union Medical College Hospital