AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Clinical Summary of 186 Cases of Orbital Autologous Fat Injection Transplantation Safely Implemented by Boosters

Ping LIU, Yi LIU ( ), Mei SONG, Fuxiu YANG, Xiaoxiao LI, Yinping WANG
Department of Burns and Plastic Surgery, the 940th Hospital of the PLA Joint Logistic Support Force, Lanzhou 730050, China
Show Author Information

Abstract

Objective

To summarize the clinical effect of using boosters for orbital autologous fat injection transplantation.

Methods

A retrospective analysis was conducted on the clinical data of patients who underwent orbital fine autologous fat injection and transplantation at the Burn and Plastic Surgery Department of the 940th Hospital of the PLA Joint Logistics Support Force from January 2019 to December 2023. The patients were treated with orbital fine autologous fat injection and transplantation using a self-developed autologous fat transplantation booster with constant pressure and micro controllability connected to a 1 mL injector, and the therapeutic effect was analyzed.

Results

A total of 186 patients who met the inclusion and exclusion criteria were included in this study, including 165 females and 21 males, with the average age of (39.0±7.1) years old (range: 23-71 years old). Of the 186 patients, 58 cases were of upper eyelid depression, 45 cases were of inner canthal depression, 34 cases were of ocular platform flattening, 6 cases were of meibomian depression, and 43 cases were of lacrimal groove depression. The transplantation volume of granular fat was 0.1-10 mL, with an average of 3.5 mL; the injection volume of nanofat was 0.5-2.0 mL, with an average of 0.5 mL. Follow up for 7 days to 4 years showed that 163 cases (87.6%) were satisfied with the results, 15 cases (8.1%) had average results, and 8 cases (4.3%) were dissatisfied. No surgical complications occurred.

Conclusion

The use of a constant pressure and micro controllable electric booster to assist autologous fat injection transplantation could achieve precision in orbital autologous fat transplantation, with high patient satisfaction, meaning that it is worthy of clinical promotion and application.

CLC number: R622 Document code: A Article ID: 1674-9081(2024)06-1342-06

References

【1】
【1】
 
 
Medical Journal of Peking Union Medical College Hospital
Pages 1342-1347

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIU P, LIU Y, SONG M, et al. Clinical Summary of 186 Cases of Orbital Autologous Fat Injection Transplantation Safely Implemented by Boosters. Medical Journal of Peking Union Medical College Hospital, 2024, 15(6): 1342-1347. https://doi.org/10.12290/xhyxzz.2024-0593

634

Views

7

Downloads

0

Crossref

1

Scopus

0

CSCD

Received: 31 July 2024
Accepted: 17 October 2024
Published: 29 October 2024
© 2024 Medical Journal of Peking Union Medical College Hospital