AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Accuracy of Contrast-Enhanced Ultrasound Diagnostic Reports for 859 Cases of Pancreatic Space-occupying Lesions

Yang GUI, Ke LYU( ), Hua LIANG, Xueqi CHEN, Wanying JIA, Tianjiao CHEN, Yuxin JIANG
Department of Ultrasound Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
Show Author Information

Abstract

Objective

To evaluate the accuracy of contrast-enhanced ultrasound diagnostic reports for pancreatic lesions.

Methods

In this retrospective study, we included patients who underwent contrast-enhanced ultrasound examination of pancreatic lesions at Peking Union Medical College Hospital from January 2017 to December 2022 and received a confirmed pathological diagnosis. Using pathological diagnosis as the gold standard, the study evaluated the accuracy of contrast-enhanced diagnostic ultrasound. It also analyzed the misdiagnosis of contrast-enhanced ultrasound in diagnosing various pathological types of pancreatic lesions.

Results

Of the 859 patients who met inclusion and exclusion criteria, 489 were male(56.9%) and 370 were female(43.1%).Their age ranged from 16 to 85 years, with a median age of 60(53, 66) years. Except for 47 pancreatic space-occupying lesions that were difficult to categorize as either benign or malignant, a total of 812 cases were included in the diagnostic efficacy analysis of benign and malignant lesions. The results suggested that the diagnostic sensitivity and specificity of contrast-enhanced ultrasound for pancreatic malignant lesions were 98.3%(95% CI: 97.1%-99.1%) and 79.0%(95% CI: 70.1%-86.4%), AUC was 0.887(95% CI: 0.863-0.908), positive and negative predictive value were 96.9%(95% CI: 95.6%-97.9%) and 87.4%(95% CI: 79.6%-92.4%), positive and negative likelihood ratio were 4.69(95% CI: 3.24-6.80) and 0.02(95% CI: 0.01-0.04). The diagnostic accuracy rate of contrast-enhanced ultrasound for diagnosing benign and malignant pancreatic lesions was 95.8%. Of the 859 lesions examined, 48 cases were misdiagnosed by contrast-enhanced ultrasound, with a misdiagnosis rate of 5.6%(48/859), including 7 cases(0.8%) of undetermined diagnosis, while the diagnostic accuracy of pancreatic ductal adenocarcinoma was as high as 98.8%. No complications occurred in any of the patients.

Conclusions

Contrast-enhanced ultrasound is a safe and effective imaging method for evaluating microvascular perfusion in various pancreatic lesions. It has significant clinical value in diagnosing both benign and malignant pancreatic lesions, particularly in diagnosing pancreatic ductal adenocarcinoma.

CLC number: R735.9;R445.1 Document code: A Article ID: 1674-9081(2024)04-0825-06

References

【1】
【1】
 
 
Medical Journal of Peking Union Medical College Hospital
Pages 825-830

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GUI Y, LYU K, LIANG H, et al. Accuracy of Contrast-Enhanced Ultrasound Diagnostic Reports for 859 Cases of Pancreatic Space-occupying Lesions. Medical Journal of Peking Union Medical College Hospital, 2024, 15(4): 825-830. https://doi.org/10.12290/xhyxzz.2024-0204

738

Views

6

Downloads

0

Crossref

0

Scopus

2

CSCD

Received: 29 March 2024
Accepted: 11 May 2024
Published: 28 May 2024
© 2024 Medical Journal of Peking Union Medical College Hospital