AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (3.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Simulation on electric-thermal-stress field for installation defects of T-type cable joint in 10 kV ring main unit

Weicheng WANG1, Qiang ZHOU1, Guangye JIA1, Kai GENG2, Zijian HAO1, Haodong WANG1
School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo 255000, China
Shandong Huineng Electric Co., Ltd., Zibo 255089, China
Show Author Information

Abstract

During the installation of the T-type cable joint of the 10 kV ring main units, defects such as impurities left behind or scratches on the cross-linked polyethylene insulation may occur due to installation negligence or non-standardization, resulting in the increase of local electric field strength and the occurrence of abnormal temperature rise, which can trigger partial discharge and even lead to fire accidents. In this paper, the JB-10/630 T-type cable joint is taken as the research object, and the electric-thermal-stress field simulation calculation model is established. Simulation and analysis are conducted for metal or semi-conductive particle installation defects and scratch installation defects at the interface of silicone rubber insulation layer/cross-linked polyethylene insulation layer and stress cone/cross-linked polyethylene insulation layer. The results show that the three installation defect regions lead to large distortion of the electric field and stress field, but the influence on the temperature field is relatively small. In addition, the distortion of the electric field becomes more severe as the radius of the metal particles increases, posing a potential threat to the insulation of the joint. Applying silicon grease paste at the scratch defect can avoid the phenomenon of stress concentration and electric field distortion around the defect.

CLC number: TM247 Document code: A

References

【1】
【1】
 
 
Electric Power Engineering Technology
Pages 106-116

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG W, ZHOU Q, JIA G, et al. Simulation on electric-thermal-stress field for installation defects of T-type cable joint in 10 kV ring main unit. Electric Power Engineering Technology, 2026, 45(10): 106-116. https://doi.org/10.12158/j.2096-3203.2026.10.011

6

Views

0

Downloads

0

Crossref

0

Scopus

Received: 08 February 2026
Revised: 30 April 2026
Published: 30 October 2026
© After publication of the article, the authors shall own the right of signature. 2026.

The authors can use or share the published article under the Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) license.