AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Hierarchical location method for harmonic sources in low-observability power distribution systems

Jianghui LI1Shenquan LIU1Xi CHEN1Dehui ZENG2Gang WANG1
School of Electric Power Engineering, South China University of Technology, Guangzhou 510641, China
Guangzhou Jiayuan Electric Power Technology Co., Ltd., Guangzhou 510610, China
Show Author Information

Abstract

To address the issue of harmonic source localization in low-observability power distribution systems, a hierarchical localization method based on physical network structure information is proposed. Firstly, according to the physical characteristics of distribution networks, the distribution rules of harmonic voltages and currents under radial topology are analyzed. Then, measurement points are reasonably placed to partition the network and construct a new topology. Based on harmonic current path identification, the number of harmonic sources and their located sections are determined. Finally, precise estimation is carried out in the determined sections to obtain the specific locations of harmonic sources. The model is established and solved based on mixed integer quadratic programming (MIQP), and simulations are implemented in MATLAB. Taking the IEEE 33-bus system as an example, the effectiveness and accuracy of the proposed method are verified by comparison with existing methods. The results demonstrate that the hierarchical harmonic source localization method presented in this paper can solve harmonic source localization problems that are closely aligned with real-world scenarios, achieving localization of harmonic sources in low-observability distribution systems where both the number and location of harmonic sources are unknown.

CLC number: TM72 Document code: A

References

【1】
【1】
 
 
Electric Power Engineering Technology
Pages 53-61

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI J, LIU S, CHEN X, et al. Hierarchical location method for harmonic sources in low-observability power distribution systems. Electric Power Engineering Technology, 2026, 45(6): 53-61. https://doi.org/10.12158/j.2096-3203.2026.06.006

3

Views

0

Downloads

0

Crossref

0

Scopus

Received: 28 August 2025
Revised: 13 November 2025
Published: 30 June 2026
© After publication of the article, the authors shall own the right of signature. 2026.

The authors can use or share the published article under the Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) license.