AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (8.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Axial Compression Behavior of Rectangular Concrete-Filled Steel Tube Columns Reinforced by Built-In Profiled Stirrup

Lan KANG( ), Xuan CHEN, Shutao HONG
School of Civil Engineering and Transportation/State Key Laboratory of Subtropical Building and Urban Science, South China University of Technology, Guangzhou 510640, Guangdong, China
Show Author Information

Abstract

Concrete-filled steel tube (CFST), as a kind of structure with broad development prospect, has good bearing capacity and plastic deformation ability. As a common form, rectangular concrete-filled steel tube column is widely used in engineering practice. Based on the two problems of inconsistent constraints on long and short sides and insufficient constraints on core concrete existing in practical application of rectangular concrete-filled steel tube, this study explored a new type of rectangular concrete-filled steel tube member, namely rectangular concrete-filled steel tube column reinforced by built-in profiled stirrup. Therefore, this study carried out the axial compression tests on 11 rectangular concrete-filled steel tube columns reinforced by built-in profiled stirrup, 2 rectangular concrete-filled steel tube columns with built-in racetrack stirrup, and 2 ordinary rectangular concrete-filled steel tube columns. It analyzed the influences of the coupling distance, steel tube thickness, concrete strength grade, stirrup spacing, stirrup diameter, built-in steel quantity on the axial compression bearing capacity and ductility of rectangular concrete-filled steel tube columns reinforced by built-in profiled stirrup. The findings reveal that reducing the thickness of the rectangular steel tube and embedding the resulting steel into the core concrete as profiled stirrup can effectively improve the axial compressive bearing capacity and ductility of the specimen, while maintaining the total amount of steel used. Additionally, the axial compression behavior of rectangular concrete-filled steel tube columns reinforced by built-in profiled stirrup can be divided into four stages: elastic stage, elastoplastic stage, plastic strengthening stage, and descending stage. Compared to ordinary rectangular concrete-filled steel tube columns, those reinforced by built-in profiled stirrup exhibit a more complete plastic strengthening stage. Based on the experimental results and parametric analysis, this study derived a calculation formula for the axial bearing capacity of rectangular concrete-filled steel tube columns reinforced by built-in profiled stirrup using an existing confined concrete constitutive model. This study can provide scientific basis and data reference for practical engineering applications.

CLC number: TU375 Article ID: 1000-565X(2024)05-0101-13

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 101-113

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
KANG L, CHEN X, HONG S. Axial Compression Behavior of Rectangular Concrete-Filled Steel Tube Columns Reinforced by Built-In Profiled Stirrup. Journal of South China University of Technology (Natural Science Edition), 2024, 52(5): 101-113. https://doi.org/10.12141/j.issn.1000-565X.230116

512

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 16 March 2023
Published: 25 May 2024
© Journal of South China University of Technology(Natural Science Edition)