AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (5.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Performance Analysis of Integrated Micro-Channel Heat Exchanger

Yunhua GAN1( )Runxi LIU1Hui YUAN2Fengming LIU2Yong LI3
School of Electric Power Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China
Guangxi Free Trade Zone Jianju Technology Co., Ltd., Qinzhou 535000, Guangxi, China
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China
Show Author Information

Abstract

In order to improve the performance of the integrated micro-channel heat exchanger, this study established the steady-state heat transfer model of an integrated micro-channel heat exchanger, and studied the influence law of the structural parameters and operation parameters on it. The integrated micro-channel heat exchanger used R245fa as working medium. It studied the effects of heat exchanger and heat exchanger heat pipe spacing on the total thermal resistance and air-side pressure drop of the system by using the model, which was verified by experiments previously. The results show that when the evaporation section air volume of the integrated micro-channel heat exchanger is 0.41 m3/s, condensing section air volume is 0.21 m3/s and the total thermal resistance of the heat exchanger system is 0.0380 m2·K/W. With the increase of circulating air volume in the condensing section and the evaporation section, the air-side pressure drop of the micro-channel heat exchanger increases, and the total thermal resistance decreases. The downtrend of the total thermal resistance of the micro-channel heat exchanger decreases gradually with the increase of air volume. In scope of this research, it is concluded that the appropriate air volume in the evaporation section is 0.45 m3/s, and that in the condensation section is 0.69 m3/s. With the increase of the integrated micro-channel heat exchanger heat pipe spacing, the total thermal resistance of the micro-channel heat exchanger increases, and the air-side pressure drop of the micro-channel heat exchanger decreases in the evaporation section. When the heat exchanger heat pipe spacing is 6 mm, the comprehensive performance of the integrated micro-channel heat exchanger is the best. The research results provide a reference for the design of cooling equipment for communication base stations and the optimization of the structure and control parameters of the micro-channel heat exchanger.

CLC number: TK124 Article ID: 1000-565X(2023)03-0013-09

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 13-21

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
GAN Y, LIU R, YUAN H, et al. Performance Analysis of Integrated Micro-Channel Heat Exchanger. Journal of South China University of Technology (Natural Science Edition), 2023, 51(3): 13-21. https://doi.org/10.12141/j.issn.1000-565X.220389

338

Views

0

Downloads

0

Crossref

0

Web of Science

1

Scopus

1

CSCD

Received: 20 June 2022
Published: 25 March 2023
© Journal of South China University of Technology(Natural Science Edition)