Wind Tunnel Test Research on the Effect of Rough Strips on Wind Loads of A Super High-Rise Building

Yi YANG( )Xin WANGChanghui JI
State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640, Guangdong, China
Show Author Information

Abstract

Rough strips such as curtain wall skeletons affiliated with the outer curtain wall envelopes of super high-rise buildings will change the flow pattern around the building, thereby affecting the wind loading characteristics of the buildings. However, the current Chinese building structural load code lacks relevant regulations in this regard. Given this, a systematic comparative study on a typical super high-rise building was performed under the two conditions of with and without the rough strips on the building surface by means of the HFPI (High Frequency Pressure Integration) test. By analyzing the changes of the wind loading characteristics such as wind pressure coefficient, base overturning moment and structural shape factor of wind load, the effect of rough strips on the wind load of the super high-rise building structure was studied. The results show that: setting of rough strips has little effect on the positive pressure on the building surface, but it will significantly reduce the absolute value of the peak negative pressure, with a maximum decline of about 39.8%; it will significantly affect the wind pressure distribution in the building corner area and lateral sides, leading to the significant reduction of the mean wind pressure coefficient and fluctuating wind pressure coefficient in the lateral sides, and the maximum decline is 24% and 30%, respectively. Overall, setting rough strips is beneficial to the wind-resist design of the building claddings. Setting of rough strips will affect the overall wind load of the structure. At a positive blowing angle of 0°, the rough strips will slightly increase the structural shape factor of the wind load in sections along the height of the building, with a maximum increase of about 8%, and the base overturning shear force and base overturning bending moment of the X-axis will slightly increase by 4.9% and 6.0%, respectively. Setting the rough strips has an impact on the wind angle of the peak acceleration at the top of the building, and can reduce the peak acceleration by about 7.91%.

CLC number: TU312.1 Article ID: 1000-565X(2023)04-0001-08

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 1-8

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YANG Y, WANG X, JI C. Wind Tunnel Test Research on the Effect of Rough Strips on Wind Loads of A Super High-Rise Building. Journal of South China University of Technology (Natural Science Edition), 2023, 51(4): 1-8. https://doi.org/10.12141/j.issn.1000-565X.220290

403

Views

1

Downloads

0

Crossref

0

Web of Science

1

Scopus

1

CSCD

Received: 16 May 2022
Published: 25 April 2023
© Journal of South China University of Technology(Natural Science Edition)