AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (6.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

LiDAR-Binocular Camera Calibration by Minimizing LiDAR Isotropic Error

Zhong CHEN( )Zichen LIUXianmin ZHANG
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China
Show Author Information

Abstract

Multi-modal data fusion of LiDAR (Laser Imaging, Detection, and Ranging) and binocular camera is important in the research on 3D reconstruction. The two sensors have their own advantages and disadvantages, and they can complement each other through data fusion to obtain better reconstruction results. In order to achieve data fusion, firstly it is necessary to unify the two data into the same coordinate system. The calibration results of the external parameters between the LiDAR and the camera are very important to 3D reconstruction. Due to sparse LiDAR point cloud and its positioning error, it is a challenge to extract feature points accurately for constructing accurate point correspondences when calibrating extrinsic parameters between LiDAR and stereo camera. In addition, most calibration methods ignore that LiDAR works on spherical coordinate system and directly use the Cartesian coordinate measurement results for calibration, which introduces anisotropic coordinates error and reduces the calibration accuracy. This paper proposed a calibration method by minimizing isotropic spherical coordinate error. Firstly, a novel calibration object using centroid feature points was proposed to improve the extraction accuracy of feature points. Secondly, the anisotropic LiDAR Cartesian coordinate error were convert into the isotropic spherical coordinate error, and the extrinsic parameters were solved through directly minimizing the spherical coordinate error. The experiments show that the proposed method has advantages over the anisotropic weighting method. The method ensures that the solution is globally optimal and the number of calibration samples required is greatly reduced on the premise of sacrificing some accuracy. With the optimal calibration error of 2.75 mm, the amount of calibration data can be reduced by about 54.5% by sacrificing 3.6% accuracy using the proposed method.

CLC number: TH122 Article ID: 1000-565X(2023)02-0001-09

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 1-9

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
CHEN Z, LIU Z, ZHANG X. LiDAR-Binocular Camera Calibration by Minimizing LiDAR Isotropic Error. Journal of South China University of Technology (Natural Science Edition), 2023, 51(2): 1-9. https://doi.org/10.12141/j.issn.1000-565X.220178

297

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 06 April 2022
Published: 25 February 2023
© Journal of South China University of Technology(Natural Science Edition)