AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (702.4 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

Multi-dimensional Comparison and Selection of High-quality Drinking Water Renovation Project Schemes for Communities

Jia-yu Zeng1, Yao Lu2, Hao-chen Cao2, Wei Li3, Wen-qi Yuan4, Shi-hu Shu1( )
School of Environmental Science and Engineering, Donghua University, Shanghai 201620, China
Shanghai Pudong Veolia Water Supply Co., Ltd., Shanghai 200127, China
China Power Construction Group Architectural Planning and Design Institute Co., Ltd., Beijing 100024, China
Shanghai Yunshui Engineering Design Co., Ltd., Shanghai 201707, China
Show Author Information

Abstract

In response to the "Water Pollution Prevention and Control Action Plan" promulgated by the State Council and to achieve the goal of direct drinking of municipal tap water in 2035, the secondary water supply net- work of an old community in Shanghai is simulated. According to the current pipeline network layout, three other different pipeline network layout schemes are proposed, which are simulated to compare the water age, pressure, flow rate and other hydraulic conditions at each point. Choosing a more appropriate transformation plan and comparing the current situation and planned one, the water level of the pool and the diameter of the pipe network are respectively optimized. The simulation results show that the water level optimization and pipe diameter optimization of the pool can significantly shorten the water age, and the pressure and flow velocity are in a more appropriate range. According to the simulation results, the multi-dimensional comparison and selection are finally selected based on the current situation of the optimization of the water level of the pool and the pipe diameter. After testing, all water quality indicators are up to standard after the renovation, and the residual chlorine attenuation coefficient is reduced by 53.3%.

References

【1】
【1】
 
 
Journal of Guangdong University of Technology
Pages 122-126

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zeng J-y, Lu Y, Cao H-c, et al. Multi-dimensional Comparison and Selection of High-quality Drinking Water Renovation Project Schemes for Communities. Journal of Guangdong University of Technology, 2023, 40(3): 122-126. https://doi.org/10.12052/gdutxb.210127

738

Views

1

Downloads

0

Crossref

Received: 30 August 2021
Published: 01 May 2023
© 2023 Editorial Office of Journal of Guangdong University of Technology

This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/).