AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.7 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Basic Study | Publishing Language: Chinese | Open Access

Effect of different pre-stretching methods on the force degradation of elastomeric chains: an in vitro study

Xiongran YU1Jiayi LIAO2,3,4Yuan FAN2,3,4Xiaoxian HUANG2Zhihua LI2,3,4( )
Department of Stomatology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China
Affiliated Stomatological Hospital of Nanchang University, Nanchang 330000, China
the Key Laboratory of Oral Biomedicine, Jiangxi Province, Nanchang 330000, China
Jiangxi Province Clinical Research Center for Oral Diseases, Nanchang 330000, China
Show Author Information

Abstract

Objective

To investigate the effect of different pre-stretching on the force degradation of elastomeric chains methods and provide experimental evidence for its application in clinical orthodontic treatment.

Methods

One control group (no pre-stretched treatment) and 15 experimental groups (pre-stretched to 25%, 50%, and 100% of the original length in 1-5 cycles) were set up by taking five loop lengths of short elastomeric chain and long elastomeric chain samples, respectively. The elastomeric chains from both the control and experimental groups were mounted on the testing fixture at identical initial lengths. To simulate tooth movement, the fixation device was adjusted to reduce the distance by 0.35 mm weekly. The remaining force of each group was measured at different time points over a 4-week period. Further, the experiment was conducted in a simulated salivary environment with additional thermal cycling.

Results

Pre-stretching length and cycles showed a significant interaction effect on the remaining force of elastomeric chains (P < 0.001). For short elastomeric chains, the groups pre-stretched to 25% (P = 0.001) and 50% (P = 0.005) of the original length for 3 cycles showed significantly higher remaining force values than the control group at 24 h. At 7, 14, 21, and 28 d, the groups pre-stretched to 25%, 50%, and 100% of the original length for 3 cycles consistently maintained higher remaining force values than the control group (P < 0.001). Within the groups of 3 pre-stretching cycles, no significant differences in remaining force were observed among the 50% group and the 25% (P = 0.617) or 100% (P = 0.229) groups at 7 d. However, at 14 d, the remaining force of the 50% group was significantly higher than that of both the 25% (P = 0.003) and 100% (P = 0.027) groups. At 21 d, the 50% group maintained a significantly higher remaining force compared to the 100% group (P = 0.020), but the difference compared to the 25% group did not reach statistical significance (P = 0.052). By 28 d, the remaining force of the 50% group remained significantly higher than that of both the 25% (P = 0.003) and 100% (P = 0.003) groups. For long elastomeric chains, the 50% pre-stretch (3 cycles) group showed significantly higher remaining force values than the control group at 8 h (P = 0.005) and 24 h (P < 0.001). Throughout the experimental period at 7, 14, 21, and 28 d, the remaining force values of the 25% (7, 14 d: P < 0.001; 21 d: P = 0.003; 28 d: P = 0.008), 50% (P < 0.001), and 100% (P < 0.001) original length pre-stretching for 3 cycles groups were consistently higher than those of the control group. Within the groups of 3 pre-stretching cycles, the remaining force of the 50% original length pre-stretching for 3 cycles group was significantly higher than that of the 25% original length pre-stretching for 3 cycles group at all of the time points from 7 to 28 d (P < 0.001). Although no statistically significant differences were observed between the 50% and 100% groups at 14 d (P = 0.068), the 50% group exhibited significantly higher remaining force than the 100% group at 7 d (P < 0.001), 21 days (P = 0.005), and 28 days (P < 0.001).

Conclusion

Appropriate pre-stretching methods can effectively delay the force degradation of the elastomeric chain. Pre-stretching to 50% original length for three cycles can maximize the delay of the force degradation of the elastomeric chain.

CLC number: R78 Document code: A Article ID: 2096-1456(2026)08-0780-11

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 780-790

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
YU X, LIAO J, FAN Y, et al. Effect of different pre-stretching methods on the force degradation of elastomeric chains: an in vitro study. Journal of Prevention and Treatment for Stomatological Diseases, 2026, 34(8): 780-790. https://doi.org/10.12016/j.issn.2096-1456.202550605

1

Views

0

Downloads

0

Crossref

0

Scopus

Received: 29 December 2025
Revised: 13 March 2026
Published: 20 August 2026
© 2026 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases

This article is licensed under a Creative Commons Attribution 4.0 International License.