To investigate the biomechanical effect of alveolar bone graft (ABG) resorption on the maxillary alveolar process under occlusal force in a patient with unilateral cleft lip and palate (UCLP) and provide evidence for the clinical application of ABG.
A 3D finite element maxillary model of an 11-year-old female patient with UCLP was generated. The occlusal force was applied to six models with different ABG resorption, namely non-resorption, upper 1/3 resorption, upper 2/3 resorption, lower 1/3 resorption, lower 2/3 resorption, and upper & lower 1/3 resorption. The properties of structures in all models were set to be linear, elastic, and isotropic. The displacement and Von Mises stress of each reference node of the alveolar process were compared and analyzed.
Under occlusal force, the most significant displacement of the alveolar process was located in the anterior area, and it decreased gradually from anterior area to both sides in all groups. The displacement values of the alveolar process under cleft side lateral occlusion were as follows: non-resorption group < lower 2/3 resorption group < upper & lower 1/3 resorption group < lower 1/3 resorption group < upper 2/3 resorption group < upper 1/3 resorption group. The displacement values of the alveolar process under centric occlusion were as follows: non-resorption group < lower 1/3 resorption group < upper & lower 1/3 resorption group < upper 2/3 resorption group < lower 2/3 resorption group < upper 1/3 resorption group. The displacement values of the alveolar process under non-cleft side lateral occlusion were as follows: non-resorption group < lower 1/3 resorption group < upper 1/3 resorption group < lower 2/3 resorption group < upper & lower 1/3 resorption group < upper 2/3 resorption group. The stress was concentrated on the premolar area on the functional side of the alveolar process, followed by the canine and molar areas in all groups. The stress values of the alveolar process under cleft side lateral occlusion were as follows: non-resorption group < lower 2/3 resorption group < upper & lower 1/3 resorption group < upper 2/3 resorption group < lower 1/3 resorption group < upper 1/3 resorption group. The stress values of the alveolar process under centric occlusion were as follows: non-resorption group < upper 1/3 resorption group < lower 1/3 resorption group < lower 2/3 resorption group < upper & lower 1/3 resorption group < upper 2/3 resorption group. The stress values of the alveolar process under non-cleft side lateral occlusion were as follows: non-resorption group < lower 2/3 resorption group < upper & lower 1/3 resorption group < lower 1/3 resorption group < upper 2/3 resorption group < upper 1/3 resorption group. Under occlusal force, the displacement and stress of the alveolar process in the non-resorption model were significantly lower than those in other models. The displacement and stress of the alveolar process in the models with resorption in the lower area of the ABG were significantly lower than those in the models with resorption in the upper-middle areas of the ABG.
After unilateral complete cleft lip and palate bone grafting, the integrity and continuity of the middle and upper parts of the alveolar process bone grafting play a key role in the biomechanical status of the alveolar process. If bone resorption occurs in the above parts, bone grafting should be considered.
This article is licensed under a Creative Commons Attribution 4.0 International License.
Comments on this article