AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Study | Publishing Language: Chinese | Open Access

Effect of tension on recovery of the donor site of a modified forearm flap

Haoran WANG1,2Ying WANG1,2Liangyu GE1Zhiping LI1Cuiling SHAO1Jian MENG1( )
Xuzhou Central Hospital, Xuzhou 221000, China
Bengbu Medical College, Bengbu 233000, China
Show Author Information

Abstract

Objective

To investigate the effect of tension on donor site recovery of modified forearm flaps (closed forearm donor site skin flaps).

Methods

From October 2018 to April 2021, 12 patients with oral cancer underwent forearm flap repair at Xuzhou Central Hospital. Handgrip strength and wrist motion were recorded before surgery. During the surgical incision at the donor site of the forearm, the triangular full-thickness skin of the donor site was used to close part of the surgical incision, and the other part of the surgical incision was directly closed and sutured. Tension was measured with a tension meter during the surgical incision at the donor site. Patients were followed up after surgery to observe whether there were postoperative complications such as necrosis and poor healing of donor site wounds, as well as forearm grip strength, wrist range of motion and appearance satisfaction.

Results

Among the 12 patients, there was only one elderly patient with postoperative necrosis near the wrist in the donor site skin, and the average tension of the patient was 0.65 kg; the lesion healed after dressing changes. All of the other patients recovered well without postoperative complications. The mean tension of 12 patients was (0.51 ± 0.05) kg. The preoperative and postoperative grip strength of 12 patients was (23.7 ± 10.3) kg and (22.3 ± 10.7) kg, respectively, and the difference was not statistically significant (t = 5.872, P<0.001). The mean range of motion of the wrist was (47.6 ± 8.3)°, (45.8 ± 5.8)°; dorsiflexion (54.6 ± 3.2)°, (53.9 ± 2.3)°; radial deviation (37.0 ± 2.3)°, (36.1 ± 2.2)°; ruler deviation (27.1 ± 1.9)°, (26.4 ± 1.3)°, respectively. The t values were 1.64, 1.636, 2.116 and 1.412, and the P values were 0.129, 0.130, 0.058 and 0.186, respectively. All 12 patients were satisfied with the appearance of the donor site of the forearm.

Conclusion

When the average tension during suturing is less than 0.5 kg, there is a lower risk of complications at the donor site of the forearm one month after surgery, a lower risk of impaired donor site function, and a greater possibility of patient satisfaction with the appearance of the donor site.

CLC number: R78 Document code: A Article ID: 2096-1456(2022)05-0345-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 345-349

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
WANG H, WANG Y, GE L, et al. Effect of tension on recovery of the donor site of a modified forearm flap. Journal of Prevention and Treatment for Stomatological Diseases, 2022, 30(5): 345-349. https://doi.org/10.12016/j.issn.2096-1456.2022.05.006

105

Views

0

Downloads

0

Crossref

1

Scopus

Received: 12 August 2021
Revised: 11 October 2021
Published: 20 May 2022
© 2022 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases